Certificate:
2411253
Project:
70099158
Master Contract:
252588
Date Issued:
2016-11-23
DQD 507 Rev. 2016-02-18
Page 2
BTLx-T
cj
0-M
m
-J-DEXC-
*
-TA12
BTLx-H
ckl
-M
m
-J-DEXC-
*
-TA12
BTL7-Vcqr-Mm-J-DEXC-*-TA12
x = 5 or 7
Q
= Quadrature output
S
= SSI output
T
= Profibus DP output
H
= CANopen output
V
= EtherCAT output
a
= Digital pulse output: I, K, L, M, N, P or R.
b
= Analog output: A, B, C, E or G.
c
= Supply voltage: 1 or 5.
d
= Analog output signal characteristic: 0, 1 or 7.
e
= Quadrature output signal frequency: 0, 1, 2 or 6.
f
= Quadrature output resolution: 0, 1, 2, 3, 5, 6, 7 or 8.
g
= Quadrature output mode/update rate: 0, 1, 2 or 4.
h =
SSI output signal type, resolution and mode: Any alpha/numeric code (up to 3 digits) not effecting the
Explosionproof protection method)
i
= BTL7 P/M Interface without DPI/IP interface: 10. BTL7 P/M Interface with DPI/IP interface: 11.
Blank for BTL5.
j
= Profibus output software configuration: 1, 2 or 3.
k
= CANbus output software configuration: 1, 2 or 3.
l
= CANbus output baud rate: 0, 1, 2, 3, 4, 5, 6, 7 or 8.
m
= Stroke length in millimeters (Maximums: BTL5 = 5080 & BTL7 = 7620)
n
= Interrogation method (if a = “R”, otherwise blank): E or I.
o
= Recirculation count (if a = “R”, otherwise blank): 1 to 16.
q
= Number of magnets or address setting (Any alpha/numeric code not effecting the Explosionproof
protection method)
r
= Protocol type (Any alpha/numeric code not effecting the Explosionproof protection method)
*
= S or M = Special electrical or internal mechanical modifications not affecting scheduled drawings or
the Explosion-proof/Flame-proof Protection methods and not exceeding 3W for the BTL5 and
5W for the BTL7. (may also be left blank)
Note: The IP68 rating includes a submersion rating of 167ft (51m) for 48 hours.
APPLICABLE REQUIREMENTS
CAN/CSA Standard C22.2 No. 0-10
General Requirements - Canadian Electrical Code, Part II
CSA C22.2 No. 25-M1966
Enclosures for Use in Class II, Groups E, F, and G Hazardous Locations
CSA C22.2 No. 30-M1986
Explosion-Proof Enclosures for Use in Class I Hazardous Locations -
Industrial Products
CSA C22.2 No. 94.1-07
Enclosures for Electrical Equipment, Non-Environmental Considerations
CSA C22.2 No. 94.2-07
Enclosures for Electrical Equipment, Environmental Considerations
Содержание BTL7-P511-M J-DEXC-TA12 Series
Страница 2: ...www balluff com...
Страница 14: ...www balluff com...
Страница 38: ...www balluff com...
Страница 62: ...www balluff com...
Страница 86: ...www balluff com...
Страница 110: ...www balluff com...
Страница 133: ...II 1 2 GD Ex d IIC T6 T5 Ga Gb II 1 2 GD Ex t IIIC T85 C T100 C Da IP68 BTL7 P511 M_ _ _ _ J DEXC TA12...
Страница 134: ...www balluff com...
Страница 148: ...16 5 1 1 2 3 BTL BTL 5 2 BTL BTL 5 BTL7 P511 M_ _ _ _ J DEXC TA12 d...
Страница 157: ...II 1 2 GD Ex d IIC T6 T5 Ga Gb II 1 2 GD Ex t IIIC T85 C T100 C Da IP68 BTL7 P511 M_ _ _ _ J DEXC TA12...
Страница 158: ...www balluff com...
Страница 172: ...16 5 1 1 2 3 BTL BTL 5 2 BTL BTL 5 BTL7 P511 M_ _ _ _ J DEXC TA12 d...
Страница 176: ...20 7 5 10 2 25 7620 3 2 6 7 7 6 fA 1 1 fA 2 2 16 P 7 1 fA 62 5 BTL7 P511 M_ _ _ _ J DEXC TA12 d...
Страница 181: ......