www.balluff.com
3
english
BTL PA0400- _ _ _ _ -C12NL _ _ 0-000S04
Magnetostrictive Linear Position Sensor – Profile Style
955204_AA ∙ EN ∙ E22; subject to modification.
Electrical connection
The electrical connection is made using a connector.
See the information about
cable routing
.
Pin
Signal
4
3
1
2
Pin assignment
of S04 (view from
above on BTL)
1 L+ (18…30 V)
2
Not assigned
1)
3 L− (GND)
4
C/Q (IO-Link communication)
1) Non-assigned wires can be connected to GND on the control side.
Cable routing
Defined ground!
The BTL and the control cabinet must be at the
same ground potential.
Magnetic fields
The position measuring system is a magnetostrictive
system. Ensure that there is sufficient distance between
the BTL and the holding cylinder and strong, external
magnetic fields.
Cable routing
All cables between BTL, control and power supply must
be routed tension-free. In order to avoid electromagnetic
interference, ensure sufficient distance to cables carrying a
heavy current and cables with high-frequency voltage
signals (e.g. of frequency converters).
Cable length
For IO-Link operation, the maximum cable length is 20 m.
Display elements
Signal
Meaning
Red flashing, 1 Hz
This signal occurs if a
measurement error occurs. The
measurement value is unknown
due to an error or outside of the
measuring range.
Red, static
General error.
Green, alternating
with LED off in a
ratio of 10:1, 1 s
period
IO-Link communication is active.
The device is ready.
Green, static
The device is ready.