6
English
Electrical data
Supply voltage U
S
12...32 V DC
No-load supply current I
0
max
≤
30 mA
Interface
IO-Link V1.1
Polarity reversal protected
Yes
Short-circuit protected
Yes
Switching frequency f
200 Hz
Accuracy according to IEC
60770
≤
±0.5% FSO BFSL
Temperature error
up to 250 bar
from 400 bar
≤
±0.5% FSO/10 K
.
≤
±0.3% FSO/10 K
Mechanical data
Housing material
Stainless steel 1.4301
Measuring cell material
up to 250 bar
from 400 bar
Ceramics Al203
Stainless steel 1.4542
Sealing ring material
Fluoroelastomer
Plug connector socket
M12, 4-pin
Process connection for material
up to 250 bar
from 400 bar
Stainless steel 1.4301
Stainless steel 1.4571
Process connection
G 1/4", G 1/2",
1/4" NPT, R 1/4"
Weight
Approx. 120 g
Ambient conditions
Ambient temperature range
–40...+85 °C
Material temperature
–40...+125 °C
Degree of protection as per
IEC 60529
IP 67 when connected
Technical data
Your pressure transmitter type
The type plate contains the exact designation and most
important technical data so that the device can be identi-
fied clearly.
Ordering code
Part number
Electr. connections
Nominal pressure
rel. nominal
pressure
Overload
pressure
Cracking
pressure
Sensor –1...2 bar
5 bar
10 bar
Sensor –1...10 bar
20 bar
35 bar
Sensor 0...2 bar
5 bar
10 bar
Sensor 0...5 bar
12 bar
15 bar
Sensor 0...10 bar
20 bar
35 bar
Sensor 0...20 bar
50 bar
70 bar
Sensor 0...50 bar
120 bar
150 bar
Sensor 0...100 bar
200 bar
300 bar
Sensor 0...250 bar
400 bar
750 bar
Sensor 0...400 bar
1200 bar
1500 bar
Sensor 0...600 bar
1200 bar
1800 bar
Pressure Transmitters with IO-Link
BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx