Balluff Network Interface
ProfiNet™
www.balluff.com
21
5
Integration
Module settings
Global diagnostics:
This function can be used to permit / suppress all diagnostics messages of the module.
(optical diagnostics signals and diagnostics in configured diagnostics modules
are not affected)
Sensor supply undervoltage:
This function can be used to permit / suppress the diagnostics message Sensor supply
undervoltage. (Optical diagnostics and diagnostics in configured diagnostics modules are
not affected)
Actuator supply undervoltage:
This function can be used to permit / suppress the diagnostics message Actuator supply
undervoltage. (optical diagnostics signals and diagnostics in configured diagnostics modules
are not affected)
Sensor short circuit at output:
With this function, the diagnostic message sensor short circuit is allowed to output of the
module / suppressed to the output of the module.
(Optical diagnostics and diagnostics in configured diagnostics modules are not affected.)
This function is valid only for channels / pins that are configured as outputs.
As inputs configured channels / pins are not affected.
Port functions
The function for every individual port pin can be defined here:
NO input
input as normally open contact
SIO mode: one IO-Link device can be configured via IO-Link and then
moved to an SIO mode in which the IO-Link port pin functions as a simple
switch input
NC input
input as normally open contact
SIO mode: as with make contact after configuration, but as break contact
input
Output
output function
For ports, which are used in IO-Link mode no configuration is nessesary at this point.
Safe state
This function is a supplement to an output configuration of the respective port pin.
For each port pin, a safe status can be predefined which is to be assumed in the event of
a loss of bus communication.
5.2.
Functions in
module properties
Description of the functions in module properties