The structure of the user parameters depends on the port configuration of the Profibus
IO-Link Master module.
The following examples show the structure of the user parameters for various port
configurations
Example 1
Profibus IO-Link Master
Port 0
– 7 Pin 4: Configured as a standard I/O port
Port 0
– 7 Pin 2: Configured as a standard I/O port
„Minimal configuration“
Byte Value
Meaning
Module
0
Station status
Norm parameters
1
WD_Fact_1
2
WD_Fact_2
3
MinTSDR
4
Indent_Number_High
5
Indent_Number_Low
6
Group_Intend
7
0x80 DPV1 Status 1
DPV1 parameters
8
0x00 DPV1 Status 2
9
0x00 DPV1 Status 3
10 0x0F Global diagnostic
Channel related diagnostic
Low voltage bus/sensor supply
Low voltage actuator supply
Head module
11 0x00
Function Port 0 … 3 Pin 4
12 0x00
Function Port 4 … 5 Pin 4
13 0x00
Function Port 6 … 7 Pin 4
14 0x00
Function Port 0 … 3 Pin 2
15 0x00 Function Port
4 … 7 Pin 2
16 0x00
Safe state Port 0 … 3 Pin 4
17 0x00
Safe state Port 4 … 5 Pin 4
18 0x00
Safe state Port 0 … 3 Pin 2
19 0x00
Safe state Port 4 … 7 Pin 2
20 0x00 Parameter Server
Conflict Resolution
Download Enable
Upload Enable
21 0x0E
Standard I/O
22 0x0E
Standard I/O
23 0x0E
Standard I/O
24 0x0E
Standard I/O