Technical data
4.5.
Ethernet
Ethernet port
2 x 100Base-Tx
Connection for Ethernet port
M12 socket, D-coded
Cable types in accordance with
IEEE 802.3
Shielded, twisted pair min. STP CAT 5/ STP CAT 5e
Data transmission rate
100 Mbit/s
Max. cable length
100 m
Flow control
Half-duplex/full-duplex (IEEE 802.33x pause)
4.6.
Function
indicators
Module status
LED
Display
Function
US
Green
Sensor supply OK
Red, flashing
Sensor supply less than < 18 V
UA
Green
Output voltage OK
Red, flashing
Output voltage low (< 18 V)
Red
No output voltage present (< 11V)
RUN
off
The device is in the INIT state
Green, flashing
The device is in the PRE-OPERATIONAL state
Green, single flashing The device is in the SAFE OPERATIONAL state
Green
The device is in the OPERATIONAL state
ERR
off
No error
Red, flashing
Invalid configuration
Red, single flashing
Local error
Red double flashing
Application watchdog timeout
Red
Error in the application
100
off
Transmission rate 10 Mbit/s
Yellow
Transmission rate 100 Mbit/s
L/A
Green
Data transfer
Status LEDs: Module status
Port/pin LEDs: