www.balluff.com
Intended use
The BML magnetic linear encoder is intended for
communication with a machine control (e.g. PLC). It is
intended to be installed into a machine or system and
used in the industrial sector. Flawless function in
accordance with the specifications in the technical data is
ensured only when using original BALLUFF accessories.
Use of any other components will void the warranty.
Non-approved use is not permitted and will result in the
loss of warranty and liability claims against the
manufacturer.
Downloading further instructions
A complete user's guide and the magnetic tape user's guide
can be downloaded from the Internet at
www.balluff.com
or requested via e-mail from
.
BML-S1G0-Q71_ -M5EZ_0-(SA26-)S28
Absolute Magnetically Coded Position Measuring System
General safety notes
Installation
and
startup
may only be performed by
trained specialists.
The
operator
is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the linear encoder will
not result in hazards to persons or equipment.
If defects and unresolvable faults occur in the linear
encoder, take it out of service and secure against
unauthorized use.
Installation and connection
27.4
25
32.4
80.3
13.7
M12x1
7.4
R4
17.4
16 +0.2
18.5 +0.2
(2x) Ø 4.3
14.8 +0.1
Active measuring surface
LED
Sensor head
1) Included in scope of delivery
Absolutcode
Absolutcode
ode
Absolutcode
Absolutcode
Absolut
Absolutcode
3
42.5
10
Active measuring surface
Magnetic tape
Right
Fr
ont
Rear
Left
NOTICE!
Interference in function
Improper assembly of the magnetic tape and sensor head may impair function of the position measuring system and lead to
increased wear or damage to the system.
►
All permissible distance and angle tolerances must be strictly complied with.
►
The sensor head may not come into contact with the magnetic tape over the entire measuring range. Contact must
also be avoided if the magnetic tape is covered by a cover strip (optional).
►
The position measuring system must be installed in accordance with the indicated degree of protection.
►
Strong magnetic fields ≥1 mT, in particular magnetic clamps, must not affect the system.
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
File no.
E227256
1
english