BML-S1G0-_7_ _-M5E_-_0-_ _
Absolute Magnetically Coded Position Measuring System
Construction and function (continued)
–Roll
The position measuring
system is connected via a
12-wire cable.
1
10
9
12
8
7
6
5
4
11
3
2
M12 plug pin assignment
(view on pin side)
+Roll
+Yaw
–Yaw
a1)
Y
1) a = 60.1 mm for linear or arched applications, or 52.4 mm for rotative
applications with BML-…-SA26-…
www.balluff.com
2
english
Application
range
Distance a
[mm]
Magnetic tape
Area without
tape
Cover
strip
Lateral
offset Y 2)
Pitch
Yaw
Roll
Linear
60.1
see user’s guide
3)
4)
3±0.5 mm
≤ ±0.5° ≤ ±0.2° ≤ ±0.5°
Arc (< 360°)
60.1±0.5
> 60 mm 3)
Ring (> 360°)
52.4±0.5
Ring on request
–
–
1) For arc and ring application
2) A larger air gap Z can be achieved with lateral offset Y is less.
3) Inserting and retracting the tape is possible.
4) Air gap without cover tape. When using the cover tape Z is reduced by
0.15 mm.
5) For ring application only
6) Only possible without cover tape.
7) Optimal conditions (no cover tape) where Z = 0.4 mm
8) Rings of diameter 243 mm and larger BML-M38-A50-A0-M243/210-E)
are available.
Application
Diameter
Z2), 4)
Linear
–
0,2…0,8 mm
Arc-shaped
motion
(< 360°)7),
Ring (> 360°)8)
243 mm 5), 6)
≤ 0.1 mm
300 mm 6)
≤ 0.1 mm
400 mm
≤ 0.2 mm
500 mm
≤ 0.3 mm
600 mm
≤ 0.4 mm 7)
700 mm
≤ 0.5 mm 7)
800 mm
≤ 0.5 mm 7)
1000 mm
≤ 0.6 mm 7)
1500 mm
≤ 0.6 mm 7)
2000 mm
≤ 0.7 mm 7)
a1)
–X
Z
+X
–Pitch
+Pitch