BIS M-62_ MANUAL
62
4
NOTE
All Balluff RS485-based
processor units’ ship with their Node ID value
set to 0.
When a powered processor unit (that is set to Node ID 0) is connected to the Subnet, it will
not initially be recognized by the Gateway until the Configuration Tag is placed in the
antenna’s RF field. After a few seconds the processor unit will display its new assigned Node
ID value in binary code from right to left or (top to bottom) using the five amber Node LEDs
on the processor unit, see Figure B, 7.
When dynamically assigning a Node ID value for a new processor unit, the Gateway will
either assign the next available Node ID value or the value that the Gateway recognizes as
offline or “
missing
” – that is, a Node ID value that previously existed, but has since
disappeared from the network.
Because the Gateway stores a backup of each Subnet Node’s configuration, should an RFID
processor unit ever fail, a replacement processor unit can be installed quickly and easily. The
new processor unit will be automatically assigned the same Node ID value and configuration
as the replaced processor unit, provided the Configuration Tag is introduced to the antenna
field after startup and then removed.
NOTE
Avoid that the configuration tag is simultaneously read by more than one
processor unit.
4.2 CONFIGURATION TOOLS
Balluffoffers the following powerful RFID configuration utilities for Microsoft Windows 2000,
XP, Vista and 7 systems:
Balluff Dashboard™
C-
Macro Builder™
These configuration tools can be downloaded from the Balluff website: www.balluff.com
Содержание BIS M-62 Series
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 7: ......
Страница 16: ...9 BIS M 371 000 A01 BIS M 372 000 A01 BIS M 373 000 A01 BIS M 370 000 A02 Figure G...
Страница 17: ...10...
Страница 21: ...BIS M 62_ MANUAL 14 1...
Страница 60: ...INSTALLATION 53 2...
Страница 77: ...BIS M 62_ MANUAL 70 4...
Страница 101: ...BIS M 62_ MANUAL 94 5...
Страница 103: ...BIS M 62_ MANUAL 96 6 The HTTP Server Main Page will be displayed...
Страница 126: ...DEVICENET INTERFACE 119 8...
Страница 185: ...BIS M 62_ MANUAL 178 10...
Страница 188: ...RFID OPERATING PRINCIPLES 181 11...
Страница 198: ...RFID OPERATING PRINCIPLES 12 No 896 712 726 EN Edition A17 Subject to modification Replaces edition L14...