BIS C-87_
Handheld Programmer
12
Getting started
3
The following settings can be made:
CodeTag type
Selection of the data carrier type. All or one particular data carrier type may be selected.
Default setting
BIS C-1xx-04
32-byte page size
BIS C-1xx-05
BIS C-1xx-11
64-byte page size
BIS C-1xx-32
BIS C-60R 001
1 byte
BIS C-60R 002
8 bytes
BIS C-60R 003
2 bytes
off
--
Use CRC check
Use the CRC checksum. If the CRC data check is enabled, the validity of the data is ensured by
a CRC checksum
(also refer to the "Data integrity" section in Section 4 "Basic knowledge",
.
If the CRC data check is not activated, the validity of the data is checked using a double read.
Sounds
Setting an audio signal for a read error ("on Error") or successful reading ("on Success").
Continuous read
Continuous read.
If this option is enabled, read requests are carried out automatically at the set interval.
[Open Reader]
Activating the read/write head.
The read/write head is activated with the settings made and the options are grayed out. The
label on the button changes to
"Close Reader"
.
Go to the
"RW Data"
tab to perform read or write operations.
[Close Reader]
Deactivate the read/write head. The settings are enabled for editing.
"Settings" tab
continued