background image

www.balluff.com 

   

     1 

Table of Contents 

 

1

 

General 

2

 

1.1.

 

Structure of the guide 

2

 

1.2.

 

Typographical Conventions 

2

 

Enumerations 

2

 

1.3.

 

Symbols 

2

 

2

 

Safety 

3

 

2.1

 

Installation and Startup 

3

 

2.2

 

General Safety Notes 

3

 

Dangerous Voltage 

3

 

Proper Use 

3

 

2.3

 

Safety Notes 

3

 

Protection from Electromagnetic Fields 

4

 

3

 

System Overview 

5

 

3.1

 

System Overview 

5

 

4

 

Installation 

6

 

4.1

 

Mutual Interference 

6

 

4.2

 

Installation in Metal 

6

 

4.3

 

Distances / Offset 

7

 

4.4

 

Permitted Angle Offset 

7

 

4.5

 

180° Rotation of the Connector Insert 

8

 

Disassembling the Holder 

8

 

5

 

Energy Transmission 

9

 

5.1

 

Derating 

9

 

Remote Current as a Function of Ambient Temperature 

9

 

Output Current of the BIC in Space 

10

 

5.2

 

Reducing the Output Power on the Base with a Decoupled Remote 

10

 

Technical Utility 

10

 

6

 

IO-Link communication 

11

 

6.1

 

Transmission Characteristics 

11

 

IO-Link Communication 

11

 

Transparent PIN2 

11

 

6.2

 

Connection Time 

11

 

7

 

Technical Data 

12

 

7.1

 

Base 

12

 

LED 1 / LED 2 

12

 

Mechanical Data 

12

 

Electrical Data 

12

 

Operating Conditions 

12

 

Pin Assignment 

13

 

7.2

 

Remote 

14

 

LED 1 / LED 2 

14

 

Mechanical Data 

14

 

Electrical Data 

14

 

Operating Conditions 

14

 

Pin Assignment 

15

 

8

 

Appendix 

16

 

8.1

 

Ordering Information 

16

 

  

Содержание BIC 1B0-IT1A7-Q40KFU-SM4A4A

Страница 1: ...BIC 1B0 IT1A7 Q40KFU SM4A4A BIC 2B0 IT1A7 Q40KFU SM4A5A User s Guide...

Страница 2: ...of the Connector Insert 8 Disassembling the Holder 8 5 Energy Transmission 9 5 1 Derating 9 Remote Current as a Function of Ambient Temperature 9 Output Current of the BIC in Space 10 5 2 Reducing the...

Страница 3: ...owing typographical conventions are uses in this manual Enumerations Enumerations is shown in the form of bulleted lists Entry 1 Entry 2 1 3 Symbols Note This symbol indicates general notes Attention...

Страница 4: ...y to the instructions provided in this User s Guide Obligations of the owner operator The device is a piece of equipment in accordance with EMC Class A Such equipment may generate RF noise The owner o...

Страница 5: ...e met Based on the EU Council recommendation 1999 519 EC in accordance with EN 62311 2008 this distance is regarded as the basic limit value or reference value for the safety of persons in electromagn...

Страница 6: ...mponent In this way the IO Link functionality of the IO Link port on the master is made available without contact on the remote Pin 2 in the system is transparent The BIC system can only be operated u...

Страница 7: ...B0 IT1A7 Q40KFU SM4A5A 200 4 2 Installation in Metal Device damage due to induction effects Metallic objects in front of and on the coil cap cause the sensing surface to be heated The sensing surface...

Страница 8: ...mm BIC 1B0 IT1A7 Q40KFU SM4A4A 5 5 BIC 2B0 IT1A7 Q40KFU SM4A5A 5 5 The system may be operated at a greater distance and or offset What is defining is the power transmitted by the system 4 4 Permitted...

Страница 9: ...teps 1 through 6 described in the following After the connector insert is rotated step 7 subsequent reassembly is performed in reverse order Disassembling the Holder 1 Loosen the grub screw 2 Pull off...

Страница 10: ...verely loaded that it collapses the status of the resulting over temperature is reported Note If the BIC system is operated with a correspondingly severe load the output voltage of the Remote collapse...

Страница 11: ...2 Reducing the Output Power on the Base with a Decoupled Remote To protect people and the environment the base component automatically reduces power which is emitted in the form of electromagnetic fie...

Страница 12: ...ate High active bidirectional from the IO Link port on the master to the IO Link device and the reverse For every status change the direction is redetermined from the side which first generates a High...

Страница 13: ...turned on Red flashing Under voltage Over voltage Red static Over temperature Mechanical Data Housing material Black plastic PBTP Housing degree of protection IP 67 only in plugged in and screwed down...

Страница 14: ...ment Power M12 4 pin connector Pin Signal 1 24 V 2 transparent pin 3 GND 0 V 4 C Q IO Link Note The digital I O signal on Pin 2 can only be sent when the BIC is in IO Link mode If the IO Link master i...

Страница 15: ...Pin 2 low Mechanical Data Housing material Black plastic PBTP Housing degree of protection IP 67 only in plugged in and screwed down state Dimensions W x H x D in mm 40 x 40 x 60 8 Weight 150 g Elect...

Страница 16: ...ent Power M12 5 pin socket Pin Signal 1 24 V 2 transparent pin 3 GND 0 V 4 C Q IO Link 5 NC Note The digital I O signal on Pin 2 can only be sent when the BIC is in IO Link mode If the IO Link master...

Страница 17: ...ler BIC 1B0 IT1A7 Q40KFU SM4A4A Base BIC 2B0 IT1A7 Q40KFU SM4A5A Remote www balluff com 16 8 Appendix 8 1 Ordering Information Product name Order code BIC 1B0 IT1A7 Q40KFU SM4A4A BIC007F BIC 2B0 IT1A7...

Страница 18: ...w balluff com Balluff GmbH Schurwaldstrasse 9 D 73765 Neuhausen a d F Germany Phone 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 939473 726 EN 04 129664 Edition C20 Replaces Edition A20 Subjec...

Отзывы: