2  Safety 

2.1  Installation and 

Startup 

 

Attention! 

Installation and startup are to be performed by trained technical personnel only. 

Skilled specialists are people who are familiar with the work such as installation 

and the operation of the product and have the necessary qualifications for these 

tasks. Any damage resulting from unauthorized tampering or improper use shall 

void warranty and liability claims against the manufacturer. The operator is 

responsible for ensuring that the valid safety and accident prevention regulations 

are observed in specific individual cases. 

 

2.2  General Safety 

Notes 

 

Commissioning and inspection 

The operating company shall be responsible for observance of locally applicable safety 

regulations. 

Before commissioning, carefully read the User's Guide. 

The system must not be used in applications in which the safety of persons depends on the 

function of the device. 

Intended use 

Warranty and liability claims against the manufacturer shall be rendered void by damage 

from: 

  Unauthorized tampering 

  Improper use 

  Use, installation or handling contrary to the instructions provided in this 

User's Guide. 

Obligations of the owner/operator 

The device is a piece of equipment in accordance with EMC Class A. Such equipment may 

generate RF noise. The owner/operator must take appropriate precautionary measures 

against this for its use. The device may be used only with a power supply approved for this. 

Only approved cables may be connected. 

Malfunctions 

In the event of defects and device malfunctions that cannot be rectified, the device must be 

taken out of operation and protected against unauthorized use. 

 

 

Dangerous 

Voltage 

 

Attention! 

Before working on the device, switch off its power supply. 

 

 

Proper Use 

 

Attention! 

Inductive coupling systems (BIC) are devices for contact-free energy and signal 

transmission in industrial environments. 

 

Use is particularly not allowed: 

  In environments with explosive atmospheres, 

  in application in which the safety of 

people or machines can be affected by transmitted signals.  

(Safety-related circuits). 

 

2.3  Safety Notes 

 

 

Caution! 

Risk of burning on hot surfaces! The sensing surface heats up even under normal 

operating conditions. Keep hands and objects away from the sensing surface. 

Metallic objects are not permitted in the in the zones defined by A and B or 

between the sensing surfaces of the Base and Remote. Fire hazard!  

 

 

 

Содержание BIC 1B0-IT1A7-Q40KFU-SM4A4A

Страница 1: ...BIC 1B0 IT1A7 Q40KFU SM4A4A BIC 2B0 IT1A7 Q40KFU SM4A5A User s Guide...

Страница 2: ...of the Connector Insert 8 Disassembling the Holder 8 5 Energy Transmission 9 5 1 Derating 9 Remote Current as a Function of Ambient Temperature 9 Output Current of the BIC in Space 10 5 2 Reducing the...

Страница 3: ...owing typographical conventions are uses in this manual Enumerations Enumerations is shown in the form of bulleted lists Entry 1 Entry 2 1 3 Symbols Note This symbol indicates general notes Attention...

Страница 4: ...y to the instructions provided in this User s Guide Obligations of the owner operator The device is a piece of equipment in accordance with EMC Class A Such equipment may generate RF noise The owner o...

Страница 5: ...e met Based on the EU Council recommendation 1999 519 EC in accordance with EN 62311 2008 this distance is regarded as the basic limit value or reference value for the safety of persons in electromagn...

Страница 6: ...mponent In this way the IO Link functionality of the IO Link port on the master is made available without contact on the remote Pin 2 in the system is transparent The BIC system can only be operated u...

Страница 7: ...B0 IT1A7 Q40KFU SM4A5A 200 4 2 Installation in Metal Device damage due to induction effects Metallic objects in front of and on the coil cap cause the sensing surface to be heated The sensing surface...

Страница 8: ...mm BIC 1B0 IT1A7 Q40KFU SM4A4A 5 5 BIC 2B0 IT1A7 Q40KFU SM4A5A 5 5 The system may be operated at a greater distance and or offset What is defining is the power transmitted by the system 4 4 Permitted...

Страница 9: ...teps 1 through 6 described in the following After the connector insert is rotated step 7 subsequent reassembly is performed in reverse order Disassembling the Holder 1 Loosen the grub screw 2 Pull off...

Страница 10: ...verely loaded that it collapses the status of the resulting over temperature is reported Note If the BIC system is operated with a correspondingly severe load the output voltage of the Remote collapse...

Страница 11: ...2 Reducing the Output Power on the Base with a Decoupled Remote To protect people and the environment the base component automatically reduces power which is emitted in the form of electromagnetic fie...

Страница 12: ...ate High active bidirectional from the IO Link port on the master to the IO Link device and the reverse For every status change the direction is redetermined from the side which first generates a High...

Страница 13: ...turned on Red flashing Under voltage Over voltage Red static Over temperature Mechanical Data Housing material Black plastic PBTP Housing degree of protection IP 67 only in plugged in and screwed down...

Страница 14: ...ment Power M12 4 pin connector Pin Signal 1 24 V 2 transparent pin 3 GND 0 V 4 C Q IO Link Note The digital I O signal on Pin 2 can only be sent when the BIC is in IO Link mode If the IO Link master i...

Страница 15: ...Pin 2 low Mechanical Data Housing material Black plastic PBTP Housing degree of protection IP 67 only in plugged in and screwed down state Dimensions W x H x D in mm 40 x 40 x 60 8 Weight 150 g Elect...

Страница 16: ...ent Power M12 5 pin socket Pin Signal 1 24 V 2 transparent pin 3 GND 0 V 4 C Q IO Link 5 NC Note The digital I O signal on Pin 2 can only be sent when the BIC is in IO Link mode If the IO Link master...

Страница 17: ...ler BIC 1B0 IT1A7 Q40KFU SM4A4A Base BIC 2B0 IT1A7 Q40KFU SM4A5A Remote www balluff com 16 8 Appendix 8 1 Ordering Information Product name Order code BIC 1B0 IT1A7 Q40KFU SM4A4A BIC007F BIC 2B0 IT1A7...

Страница 18: ...w balluff com Balluff GmbH Schurwaldstrasse 9 D 73765 Neuhausen a d F Germany Phone 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 939473 726 EN 04 129664 Edition C20 Replaces Edition A20 Subjec...

Отзывы: