background image

BVRD Network

Installation Instructions

Manual name: BVRDNET

Issue: 3

ECR: 3326

Date of issue: Oct 2017

Содержание BVRDFIF

Страница 1: ...BVRD Network Installation Instructions Manual name BVRDNET Issue 3 ECR 3326 Date of issue Oct 2017...

Страница 2: ...e http www baldwinboxall co uk This equipment has been designed and manufactured to conform to the following EC Standards EMC EN55103 1 Environment Classification E1 EMC EN55103 2 Environment Classifi...

Страница 3: ...______3 BVRDCIF Copper Network ____________________________4 Cable Requirements 4 Cable Connections to BVRDCIF 4 BVRDFIF Fibre Network ______________________________6 Fibre Optic Cable Requirements 6...

Страница 4: ...BVRD Network Installation Instructions iv BVRDNET issue 3...

Страница 5: ...and the use of the information is therefore restricted only to those persons duly authorised by Baldwin Boxall Communications Limited Do not reproduce transcribe store in a retrieval system or transla...

Страница 6: ...ns and Notes Warnings describe potential threats to health or life e g WARNING Before attempting to remove this component ensure the Mains Power Supply and Battery Backup have been disconnected Cautio...

Страница 7: ...continue to function in the event of cabling damage at a single location The network can be either Copper Multi Mode Fibre Single Mode Fibre or a combination of both using the BVRDCIF BVRDFIF and BVR...

Страница 8: ...T Module The BVRDNET is fitted inside the BVRD2M 4 and is a factory fit option only BVRDFIF S Fibre BVRDCIF Copper Interface The BVRDCIF and BVRDFIF S interface modules are DIN rail mounted and use st...

Страница 9: ...and connect to the BVRD2M 4 using standard RJ45 patch leads BVRDFIF S modules require a Wurth 742 71221 cable ferrite installing so that the cable passes through the ferrite 2 times The ferrite should...

Страница 10: ...r Core Cable should be used with a cross sectional area of either 1mm2 untwisted or 0 5mm2 twisted Baldwin Boxall recommend using 1 5mm2 cable The typical maximum length of cable between units is as f...

Страница 11: ...ctions should be connected as shown in Figure 2 3 with one RJ45 in the Lower P3 socket and the other RJ45 in the Upper P2 socket of the BVRDCIF modules NOTE The Tx and Rx pairs are swapped between the...

Страница 12: ...ingle mode fibre OS1 9 125 and OS2 9 125 Fibre optic cable with ST Transmit and Receive connections should be used Two cables Tx and Rx connect between each BVRDFIF The typical maximum distance betwee...

Страница 13: ...itched on 3 1 COPPER NETWORK USING BVRDCIF MODULES 3 1 1 Local Network connection Before connecting the site wiring to the BVRDCIF ensure there are no shorts between the site wiring conductors and ens...

Страница 14: ...s match the screen printed colour codes or is consistent with the connection details of the Local unit if the site cables do not match the screen printed colour codes Ensure the Remote BVRD2M 4 is swi...

Страница 15: ...VRDFIF S module NOTE The LED on the BVRDFIF S will not flash until the network is connected and receiving data 3 2 2 Remote Network connection Go to the Remote unit Ensure the Remote BVRD2M 4 is switc...

Страница 16: ...between the Remote unit and the Local Unit Ensure the TX cable from the remote unit is connected to the local RX and the local TX is connected to the remote RX It is possible to check the Local Hardwa...

Страница 17: ...onnectors are used P2 on one end and P3 on the other end Figure 3 1 BVRDCIF Copper Conductors 3 3 4 Fibre Network BVRDFIF S Specific Ensure the correct fibres are in use using visible Light Source if...

Страница 18: ...sical access to the equipment racks is limited It is possible to connect each reset seperately for individual routers or all routers on the network can have these reset connections connected together...