Section 4
Operation
Operation 4-1
MN2488
Preoperational Checklist
Before the POW’R LITE is put into service, the items in Table 4-1 must be checked.
Table 4-1 Pre
−
Operation Checklist
-
Check unit for obvious structural damage.
-
Make sure light mast is secure.
-
Check that light fixtures are secured in place.
-
Check that front and rear jacks are secure into position and operate properly.
-
Inspect tires for damage.
-
Make sure tires are inflated to 32 psi and that lug bolts are tightened to 90 lb−ft.
-
Inspect engine/generator parts for any obvious damage or loose parts.
-
Inspect control panel for damage or loose fasteners.
-
Inspect mast wiring for cuts, abrasions, and loose connections.
-
Check light fixtures for lamp, reflectors, and lens damage.
-
Inspect both winches, cables, cable clamps, and pulleys for damage and proper operation.
Figure 4-1 POW’R LITE Component Identification
Jack
Coupler
Coupler Handle
Safety
Chains
Light Mast
Trailer
Outriggers
Light
Fixtures
Trailer
Muffler
Lift
Slots
Tilt
Winch
Lift
Winch
Tilt Lock
Mast
Lock
Engine
Compartment
Tow
Bar
Lift
Slot
Lift
Slot
Содержание POW'R LITE PL6000K
Страница 1: ...POW R LITE PL6000K Portable Light Tower Installation Operating Manual 9 06 MN2488 ...
Страница 4: ...ii Table of Contents MN2488 ...
Страница 12: ...2 2 General Information MN2488 ...
Страница 17: ...Receiving Installation 3 5 MN2488 Figure 3 3 Trailer Harness ...
Страница 18: ...3 6 Receiving Installation MN2488 ...
Страница 30: ...5 4 Troubleshooting and Maintenance MN2488 Figure 5 7 Flood Light Mast Wiring ...
Страница 31: ...Troubleshooting and Maintenance 5 5 MN2488 Figure 5 8 Engine and Control Wiring ...
Страница 32: ...5 6 Troubleshooting and Maintenance MN2488 ...
Страница 33: ...Baldor District Offices ...