5
WARNING! HIGH VOLTAGE IS PRESENT IN THIS DRIVE. DISCONNECT MAIN
POWER BEFORE MAKING CONNECTIONS TO THE DRIVE. DO NOT
ADJUST TRIMPOTS WITH THE MAIN POWER APPLIED. IF
ADJUSTMENTS ARE MADE WITH THE MAIN POWER APPLIED, AN
INSULATED ADJUSTMENT TOOL (PROVIDED) MUST BE USED AND
SAFETY GLASSES MUST BE WORN. FIRE AND/OR ELECTROCUTION
CAN RESULT IF CAUTION IS NOT EXERCISED.
WARNING! HIGH VOLTAGE IS PRESENT IN THIS DRIVE. DISCONNECT MAIN
POWER BEFORE MAKING CONNECTIONS TO THE DRIVE. TO PREVENT
ACCIDENTAL CONTACT WITH HIGH VOLTAGE, IT IS REQUIRED THAT
THE COVER BE PROPERLY INSTALLED AFTER ALL SETUP,
CONNECTIONS, AND ADJUSTMENTS ARE COMPLETE. THIS REDUCES
ELECTRICAL SHOCK HAZARD. FAILURE TO OBSERVE THIS WARNING
COULD RESULT IN ELECTRICAL SHOCK OR ELECTROCUTION.
WARNING! AUTOMATIC START AND RESET: JUMPER J3 IS FACTORY SET TO THE
“AUTO” POSITION TO AUTOMATICALLY START THE DRIVE WHEN THE
POWER IS APPLIED AND THE ON/OFF AC LINE SWITCH IS SET TO THE
“ON” POSITION.
WARNING! THE DRIVE WILL AUTOMATICALLY RESTART AFTER A FAULT HAS
CLEARED. IF AN I
2
T OR SHORT CIRCUIT OCCURS, THE DRIVE MUST
BE RESTARTED BY SETTING THE ON/OFF AC LINE SWITCH TO THE
“OFF” POSITION FOR A MINIMUM OF 5 SECONDS.
WARNING! DO NOT DEPEND ON THE PILOT LIGHT OR THE PC BOARD MOUNTED
LEDS FOR A GUARANTEED POWER OFF INDICATION. BE SURE ALL AC
POWER IS “OFF” BEFORE SERVICING THE DRIVE TO AVOID
ELECTRICAL SHOCK HAZARD.
WARNING! MAKE SURE THAT THE POTENTIOMETER IS SET FULLY
COUNTERCLOCKWISE PRIOR TO APPLYING POWER. IF THIS IS NOT
DONE, THE MOTOR WILL RUN AT THE SPEED SETTING AT POWER UP.
THIS MAY CAUSE BODILY INJURY IF ONE IS IN CLOSE PROXIMITY OF
MOVING PARTS.
CAUTION!
1. Some motors have low speed characteristics, which cause overheating and
winding failure under light load or no load conditions. If the motor is operated in
this manner for an extended period of time, it is recommended that the unloaded
motor current by checked from 2-15Hz (60-450RPM) to ensure motor current does
not exceed the nameplate rating. Do not use motor if the motor current exceeds
the nameplate rating.
2. It is recommended that the drive be used with Inverter Duty or TENV motors.
Содержание ID5601-EO