SERVICE BULLETIN SB3063

Rev A  12/08

832442

Balcrank Lubrication Equipment Warranty Statement

All Balcrank equipment sold by authorized Balcrank distributors is warranted to their original customer to be free from defects in materials and workmanship 

for a period of one year from the date of sale to that customer. Selected Balcrank equipment carries warranty terms for a more extended period as defined in 

the Balcrank Lubrication Equipment & Accessories User Price List, wherein a “lifetime” warranty represents a warranty period of thirty years. Within the initial 

one-year warranty period, Balcrank will repair or replace all Balcrank equipment determined by Balcrank to have defective materials or workmanship. For 

equipment carrying more extended warranties, Balcrank will repair or replace the product including parts and labor during the first full year and will provide 

parts only for the remainder of the warranty period.

This warranty applies only to equipment installed and operated according to applicable Balcrank Service Bulletins and Installation Instructions.

Any equipment claimed to be defective must be returned, freight prepaid, to an Authorized Balcrank Service Center (ASC). Upon receiving candidate warranty 

equipment from a customer, ASC will: 1) diagnose to determine the warrantable condition of the equipment, 2) submit, prior to repair or replacement, a 

request to Balcrank for warranty authorization, then 3) in cooperation with Balcrank, proceed with repair locally or forward the equipment to Balcrank and 

obtain replacement. If the part(s) or equipment items are found defective upon inspection by Balcrank, they will be repaired or replaced, and then will be 

returned to the ASC. If Balcrank finds the claimed part(s) or equipment not to be defective, the ASC will receive written authorization from the original 

customer, and then repair them for a reasonable charge to the customer, which will include all applicable parts, labor, and return transportation costs.

Optionally, the customer may submit certain eligible products directly to Balcrank for warranty return by using Balcrank Lubrication Equipment Direct Service 

Warranty Procedure. Eligible products are defined in the Balcrank Lubrication Equipment & Accessories User Price List. Refer to the Balcrank web site www.

balcrank.com for a copy. 

Any equipment returned to Balcrank must have the Warranty Service Claim number (WSC#) clearly marked on the outside of the carton. Balcrank’s sole 

responsibility is for defects in material and workmanship, and Buyer’s sole and exclusive remedy hereunder, shall be limited to repair or replacement of the 

defective part or equipment.

This warranty does not cover, nor shall Balcrank be liable for repair or replacement of parts or equipment resulting from general wear and tear through use, 

or damage or failure caused by improper installation, abuse, misapplication, abrasion, corrosion, insufficient or improper maintenance, negligence, accident, 

alteration, or substitution of non-Balcrank parts.

Furthermore, the Warranty for Lubrication Equipment and Accessories does not cover the following specific conditions:

•  Failure or damage to equipment caused by dirt or debris in compressed air lines and fluid lines. This includes, but is not limited to, clogged inlet filters, 

strainers, or regulators; fluid meters; control handles; fluid tips; and valves.

•  Failure of normal wear parts including but not limited to: o-rings, packings, seals and valves unless originally improperly installed by the factory.  

•  Products placed in applications for which their use was not intended. Examples include but are not limited to Lubricant pump being used    

 

to pump solvents, or placing equipment intended strictly for indoor use outdoors 

•  Damage to equipment resulting from operation above and beyond Balcrank’s recommendations.

•  Leaks at air and fluid fittings and connections.

•  Damage caused by thermal expansion whenever adequate pressure relief was not included in the system.

•  Loose suction tubes on pumps.

•  Incorrect hose reel spring tension, requiring adjustment.

THERE  ARE  NO  OTHER  WARRANTIES,  EXPRESSED  OR  IMPLIED,  INCLUDING  WARRANTIES  OF  MERCHANTABILITY  OR  FITNESS  FOR  A 

PARTICULAR PURPOSE. IN NO EVENT SHALL BALCRANK BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, OR OTHER DAMAGES OF SIMILAR 

NATURE, INCLUDING BUT NOT LIMITED TO LOST PROFITS, LOST PRODUCTION, PROPERTY DAMAGE, PERSONAL INJURY, WHETHER SUFFERED 

BY BUYER OR ANY THIRD PARTY, IRRESPECTIVE OF WHETHER CLAIMS OR ACTIONS, LEGAL OR EQUITABLE, FOR SUCH DAMAGES ARE BASED 

UPON CONTRACTS, WARRANTY, NEGLIGENCE, STRICT LIABILITY, OR OTHERWISE. ANY CLAIM OR ACTION FOR BREACH OF WARRANTY MUST 

BE BROUGHT WITHIN TWO (2) YEARS FROM THE DATE OF SALE TO THE ORIGINAL CUSTOMER.

Revision Log:
New Release - 12/07

Rev. A - Updated warranty statement

Содержание FUSION 3110-013

Страница 1: ...oughly read and understand this manual before installing operating or servicing this equipment ADMINISTRATION SETUP MANUAL FUSION DISTRIBUTED CONTROL FLUID MANAGEMENT SYSTEM Model 3110 013 Distributed...

Страница 2: ...pplication and use of the equipment described Should the equipment be used in a manner not specified by Balcrank Products Inc the protection provided by the equipment may be impaired Questions or Serv...

Страница 3: ...anagement 14 File Management 16 System Setup 21 System Entity 26 System Product Tree Configuration 29 System Network Tree Configuration 30 System Network Installation Process 32 Process to Modify Add...

Страница 4: ...re that there is reliable communications at all times Com munication distances are typically up to 300 feet or more and there is a remote antenna available for situations where multiple buildings are...

Страница 5: ...is for connection to an optional printer The cable without any markings is for the host connection All cables have the same pin outs listed below Connections Distributed Control Keypad Plugs 9 pin RS...

Страница 6: ...provide the fluid and amount to be dispensed The results of the dispense will then be stored on the PC Distributed Control Dispense with Host Operation In this configuration the PC is used to configur...

Страница 7: ...Screen To Logon on to the OMS Distributed Control System enter the 4 digit system password and click he LogOn button The system password is initially set to 0000 and can be changed using the system i...

Страница 8: ...down using the bar on the right side of the screen To select an option from the Main menu click on the desired item To return to the Work Order screen click on the LOGO in the upper left hand corner o...

Страница 9: ...it The meter must be programmed to dispense in the same unit as the tank The queuing feature of the system allows for work orders to be entered into the system and have the dispense performed at some...

Страница 10: ...ect the time frame of historical information to be displayed Use the pull down menu to select a different display option Tank Level Screen The Tank Level screen is for informational purposes only It s...

Страница 11: ...f fluid available is based on the summed value Pending WO Screen The pending work order screen shows all the orders in the system that are available to be worked on After a work order is completed the...

Страница 12: ...th unit of measure for dispensing from the tank The second section shows the id of the Zone keypad and the Hose Meter id numbers associated to the Zone keypad It also shows the fluid that is to be dis...

Страница 13: ...rovides a simple display of the system configuration data Refer to Section System Initialization for detailed information No data can be modified from this screen To return to the main menu options cl...

Страница 14: ...pin number and click create Leading zeros must be included in the Pin id number The user name can be up to 16 characters in length Note 8888 is a reserved PIN id and cannot be assigned to a user To d...

Страница 15: ...rogram Note DO NOT EXIT X the program The Program will automatically download all user information to the Zone Keypads It is suggested this process take place at the end of the day After completion of...

Страница 16: ...ROTOCOL Using the browse feature go to the folder All Saved files are located in the following directory C program files Badger HighEnd Admin High End Export This is the location the user will go to w...

Страница 17: ...and file name for the SAVED SETUP FILE Pending WO Screen Standard popup menu for opening a file The File On going WO Open files containing the following tables ALL PENDING WO By opening the files the...

Страница 18: ...Open files containing the following tables WORK ORDER RESULTS By opening the files the software will automatically erase and update all the tables content Standard popup menu for saving a file The Fil...

Страница 19: ...oftware will automatically erase and update all the tables content Standard popup menu for saving a file The file setup open files contains ALL the tables Standard popup menu for saving a file The fil...

Страница 20: ...eleted from the database Be sure that you have selected the time frame you want to keep before clicking the OK button It is recommended that you save the Work Order results using File Export prior to...

Страница 21: ...selection and should reflect the geographical region or frequency that you are operating the system in Europe is for 868 mhz operation and the US is for 915 mhz operation The correct selection is requ...

Страница 22: ...22 Configuration Screen NOTE Host communication is not covered in this manual...

Страница 23: ...mount of time certain screen will appear on the DC Keypad before the DC Keypad will move to the next screen Pressing Enter on the DC Keypad will override this time and the next screen will appear Ente...

Страница 24: ...ll appear on the Dispense Keypad every dispense request YES NO selection Timeout Zone Keypad Timeout This timeout is the amount of the Zone Keypad will sit idle no buttons pushed during the dispense r...

Страница 25: ...Control Keypad keyboard YES NO selection Default is YES Keypad timeout Zone Keypad Timeout This timeout controls the amount of time the Zone Keypad will wait for the Distributed Control Keypad to ackn...

Страница 26: ...and will appear on the screen next to its fluid id number To Modify an existing fluid name type the new name in the box next to the one to be modi fied and click the modify button The name of a fluid...

Страница 27: ...en a new Meter is added The Meter address is found on a tag inside the battery compartment of the meter The format of the address is x xxx xxx xxx and is a 10 digit number When the address is entered...

Страница 28: ...s in the new dispense keypad address box and click the create button The system will assign it the keypad id number automatically To delete a keypad click the delete box next to the keypad to be remov...

Страница 29: ...der the desired fluid branch Then click the add button The tank id tank level and dispensing unit will then be displayed below the fluid id When a tank has been associated to a fluid it will no longer...

Страница 30: ...o A Zone keypad must first be defined in the entity Zone keypad table by entering the unique id number found on the back of the keypad Tank and meter ids must also have been previously added in the en...

Страница 31: ...the Zone keypad The key thing to remember is that a hose meter id can only be associated to one Zone keypad When the hose meter is selected from the list it will no longer be included in the pull down...

Страница 32: ...ions interface program between the Distributed Control Keypad and the PC 1 The KPS icon is located at the bottom right hand corner of the screen 2 Double click on the icon and the program will appear...

Страница 33: ...54 Flow 7C Network configuration terminated Ok 09 08 03 13 39 54 Starting listener 09 08 03 13 39 54 Listener is down 09 08 03 13 39 55 Starting listener 09 08 03 13 39 55 Listener is down 09 08 03 13...

Страница 34: ...EXIT X the program The Program will automatically Re initialize and download all of the USER information to the Zone Keypads It is suggested this process take place at the end of the day After complet...

Страница 35: ...ize the KPS program Note DO NOT EXIT X the program The Program will automatically send a test communications frame to the Distributed Control Keypad If there is a problem in the communications the dis...

Страница 36: ...ached from the meter 5 Press MODIFY 6 Insert Hose Meter in the Network Tree Open The KPS program 1 Double click on the KPS icon on bottom corner of the screen 2 Under Edit click on the INIT 3 Minimize...

Страница 37: ...the KPS program When the KPS program is running the icon will look like this If KPS is not running the KPS icon will have a RED slash through it or there will be no icon displayed in the lower right...

Страница 38: ...this mode the DK will request WO validation from the MK how ever the DK will continue with the WO process if there is no communications with the MK To Enter the Emergency Mode 1 Enter the Supervisor...

Страница 39: ...number for validation the Zone Keypad DK displays Action When the PC Host connection with the Distributed Control Keypad has failed the Distributed Control Keypad may be put into an Emergency Mode of...

Страница 40: ...is rees tablished with the MK All WO result data will be automatically transmit to the MK and PC at that time Zone Keypad Communications Test Archive on PC YES NO To test DK communication with MK 1 En...

Страница 41: ...DCKP sends the WO to the PC Flow D PC sends a validation to DCKP Flow E DCKP sends a validation to ZKP Flow F ZKP sends dispense to Meter Flow G Meter sends result to ZKP Flow H ZKP sends result to DC...

Страница 42: ...CKP sends the WO to the Host Flow D Host sends a validation to DCKP Flow E DCKP sends a validation to ZKP Flow F ZKP sends dispense to Meter Flow G Meter sends result to ZKP Flow H ZKP sends result to...

Страница 43: ...43 Notes...

Страница 44: ...Lubrication Equipment Accessories User Price List Refer to the Balcrank web site www balcrank com for a copy Any equipment returned to Balcrank must have the Warranty Service Claim number WSC clearly...