24
Label
Database
Comments/Rules
Mileage type
Zone Keypad Mileage Type:
- Will the Vehicle Mileage be
tracked in KM or Miles
KM/MILES selection
N Field
information
Zone Keypad N Field information:
- Will the 8 digit Numeric Free
Field be used
If yes is selected for N Field and AN Field:
1. These two fields will appear in the
Dispense Screen for data entry.
2. These two fields will appear on the
Dispense Keypad every dispense
request.
YES/NO selection
AN Field
information
Zone Keypad AN Field information:
- Will the 10 character
alphanumeric Free Field be
used
If yes is selected for N Field and AN Field:
3. These two fields will appear in the
Dispense Screen for data entry.
4. These two fields will appear on the
Dispense Keypad every dispense
request.
YES/NO selection
Timeout
Zone Keypad Timeout:
- This timeout is the amount
of the Zone Keypad will sit idle
(no buttons pushed) during the
dispense request process prior
to return to the main screen.
- If this timeout is reached
prior to completing the
request the USER must reenter
PIN to begin WO request.
Enter a decimal value from
10-255.
One second increments
Default is 10 seconds
Hose inactive
timeout
Zone Keypad Hose Inactive Timeout:
- The Hose Inactive timeout
controls the amount of time
the Hose may sit idle before it
will automatically close out the
Work Order and Lockout.
- This time begins on the Hose
when it receives the dispense
quantity from the dispense
keypad.
NOTE: Please allow enough time for
TOP-OFF to occur
RECOMMENDED TIMEOUT IS 300-500.
Enter a decimal value
from
10-65535.
One second increments
Default is 400 seconds