Symptom Cause
Solution
5. System has power and
Pump is not operating.
Check the air supply to the pump
goes into ready mode,
and the pump air solenoid valve.
but no fluid can be
dispensed.
Out of fluid.
Check the fluid level in the storage
container.
Control solenoid valve not
Check valve for energized position.
operating.
Outlet of pump is blocked.
Check impulse meter and control
solenoid valve for blockage.
Defective station selector
Return the unit for repair.
switch.
System not properly wired.
Recheck electrical connections and
rewire as specified.
Cable not connected or properly
Plug in cable connector.
seated.
6. Fluid does not cut off
Impulse meter set up for the
Check the impulse meter for the
at the correct preset
wrong units.
correct volume per pulse.
Impulse meter cam plate not
Check the position of the pulse
actuating pulse switch at each
switch in relation to the cam lobes.
cam lobe. The pulse switch is
Also check for broken cam lobe.
out of position.
Adjust or replace as required per
meter instructions.
Defective unit.
Return the unit for repair.
7. Remote “Ready” light
Remote “Ready” light bulb
Replace bulb.
will not come on, but
burned out.
the console “Ready”
light does.
Remote “Ready” light improperly
Correct or replace remote wiring.
wired or faulty wiring.