CONSOLE SETUP INFORMATION (CONTINUED)
Entering the Setup Menu:
-
Start with the unit powered OFF
-
While pressing the “Zero” and “Up arrow” buttons, power on unit by turning key to “ON” position.
SETUP DISPLAY
Pulse Calibration Factor:
-
Can be set to 1 through 5, or negative 1 through 5, allowing you to adjust pulses per unit up or down 5
pulses.
•
Use the “Up arrow” key to scroll between Quarts, Gallons, Pints, and Liters.
•
Press the “SET” button to enter edit mode (The Pulse Calibration Factor will begin flashing)
•
Use the “Up arrow” key to change the numerical values from 0 to 5, -1 to -5
•
Press the “SET” button to exit edit mode
•
When finished press the “TOTAL” button to save changes.
•
Wait till the display looks like -->
•
Power unit off with key
Units
Pulse
Calibration
Factor
# Pulses
per unit
•
Example
•
Setting the Pulse Calibration Factor to “-2” would look like:
•
When powering the unit on the display will show:
•
Unit set for Quarts and 153 pulses per unit