Misfiring

If a head misfires at lower power, you probably have a flash tube that is either
new or hard to trigger. Fire that tube at full power 50 times to "break it in". It
should fire correctly from now on.

Reset

To display additional CONCEPT P4 information, maintain the O/1 Auxiliary
ON/OFF button pressed until C O N C E  P T    P  4  is  displayed.

The software version number will then be displayed following the U. display:

If you maintain the ON/OFF button pressed, the unit is reset to its original factory
configuration.

The number of flashes made is then displayed. If you maintain the ON/OFF but-
ton pressed, the display will zero itself (wait until the 0's appear).

Changing the Fuse

Turn the unit off and unplug the A/C cord if you need to change the fuse on your
CONCEPT P4.

Unscrew the fuse holder using a flat-blade screwdriver. Replace the fuse with
the same rated fuse.

Flash Duration and Color Temperature

As a general rule, raising and lowering power using the variators will not affect
flash duration but will modify color temperature. On the other hand, using the
power selector at the back of the head will change flash duration while maintain-
ing color temperature.

For shorter flash duration, set the head at the lowest power setting using the
head power selector. We recommend adding a second flash tube (in the "cross"
position), which reduces flash duration up to 40%.

For optimal color temperature, use clear shells when lighting with diffusing
accessories, and yellow shells with direct reflectors.

Travel Recommendations

When going on location make sure the CONCEPT P4 and the heads are proper-
ly packed. Take special care in guarding against shocks and in protecting the
glass (flashtube, model lamp, Pyrex shell) of the head. If necessary, remove the
glass and protect it separately.

Always carry a spare synchro cord and spare glass.

We hope you wil enjoy the use of your new CONCEPT P4, and we thank you
again for your purchase.

Please mail or fax any comments to:

BALCAR S.A.
Rue des Coutures, Z.I. Sud de Torcy
77200 Torcy FRANCE
tel: (33)(0) 1 64 11 63 90 - fax: (33)(0) 1 64 11 63 91
e-mail : [email protected] - http://www.balcar.fr

MADE I

10 A Slo. 220 V
20 A Slo. 110 V

Caution

99500

CP4  instructions

Содержание CONCEPT P4

Страница 1: ...A B C D MADE IN FRANCE 100 240 V 50 60 Hz TEST 10 A Slo 220 V 20 A Slo 110 V A CONCEPT P4 Auto Auto Max 100 ind X B C D Rue des Coutures Z I Sud de Torcy 77200 TORCY FRANCE Tel 33 0 1 64 11 63 90 Fax 33 0 1 64 11 63 91 99500 CP4 instructions ...

Страница 2: ...ERE ARE ABSOLUTELY NO USER SERVICEABLE PARTS INSIDE THE CONCEPT P4 Never open the unit and never attempt to repair it You might be injured by the high voltage BALCAR maintains repair stations around the world to give you the best service 2 ALWAYS DISCHARGE and UNPLUG the light heads before removing the Pyrex shell and touching the flashtube or the model lamp 3 NEVER use fuses rated higher than tho...

Страница 3: ...l Lamp Selector When pressed normally changes model lamp modes model lamps off no mode selected Auto Each model lamp is proportional to the flash power of each head 10 is 100 9 is 50 8 is 25 etc Auto Max Each model lamp is proportional to the flash power of each head but there is always one model lamp at 100 the other model lamps are proportionally lower 100 independent The level of each model lam...

Страница 4: ...rovided with your unit The CONCEPT P4 is powered by turning the ON OFF switch of the A C plug assembly to the ON position This switch is also called the hardware on off because it actually cuts off the A C supply line when in the OFF position The 0 1 switch at the bottom left of the control panel is called the auxiliary on off It is used to actually turn the unit on or off after the hardware switc...

Страница 5: ...k the up key 5 times to 8 7 Power ratios between two heads are the difference between their displays For example if Head A is at 8 0 and Head B is at 9 5 the power ratio is 1 5 1 1 2 f stops the difference between 9 5 and 8 0 When using the Master Up or Down keys notice that all displays increment or decrement together therefore preserving the light ratio between each head as the difference betwee...

Страница 6: ...or switch at the back of each head is in an equivalent position 5 AUTO MAX mode This mode is identical to the AUTO mode but the intensity of the model lamp of the head at the highest flash power is set at 100 In order to preserve proportionality all other model lamp values are increased accordingly The following example summarizes the differences between each mode Head A B C Flash Power 8 0 6 5 9 ...

Страница 7: ... Cell The photocell is activated by pressing the Photo Cell button The yellow LED indicator is on when the cell is active 100 charge Audible Signal The 100 charge audible signal is activated by pressing the audible signal but ton The yellow LED indicator is on when the signal is active You can flash as soon as the audible signal starts Sequencer The CONCEPT P4 Sequencer is used to create multiple ...

Страница 8: ...he variators will not affect flash duration but will modify color temperature On the other hand using the power selector at the back of the head will change flash duration while maintain ing color temperature For shorter flash duration set the head at the lowest power setting using the head power selector We recommend adding a second flash tube in the cross position which reduces flash duration up...

Отзывы: