In the Ind. (Independent) mode, the up and down arrows are used to raise or
lower the power of the model lamp independently from the power of the flash.
This can only be done if the Ind. mode is selected. Note that the Model Lamp
Selector button must remain pressed long enough before using the individual
head controls.

6.

SYNCHRO CONTROL

Synchro Hardware

The CONCEPT P4 is triggered using the TEST button/100% charge indicator,
the Synchro Jack "X" plug, the Photocell (if enabled) or the Sequencer.

The unit will be allowed to trigger once it is 100% charged, and only if the TEST
button (or X sync contact) was previously released.

If there is a short-circuit in the synchro connection, the unit will not trigger again
(and the 100% indicator will not turn on), until the short is eliminated.

A single head is triggered by pressing the TEST button at the back of that head.
If the photo cell is turned on, the other heads will likely also trigger. By maintain-
ing the head TEST button pressed, the individual head display will turn off: this is
useful when you have lost track of what head is connected where.

Photo Cell

The photocell is activated by pressing the Photo Cell button. The yellow LED
indicator is on when the cell is active.

100% charge Audible Signal

The 100% charge audible signal is activated by pressing the audible signal but-
ton. The yellow LED indicator is on when the signal is active.

You can flash as soon as the audible signal starts.

Sequencer

The CONCEPT P4 Sequencer is used to create multiple flash sequences. It is
activated by pressing the Sequence Selector. If activated, the decimal display
and the yellow LED indicator turn on.

There are 2 sequence modes:

1.

Count-down mode:

Press the sequence button until the number of flashes you want is dis-
played. Once the unit is triggered (using the TEST button, the "X" syn-
chro plug or the photocell), the CONCEPT P4 will flash as many times
as you requested as soon as it is at 100% charge. The display counts
down until it reaches 0, then resets itself, ready for a new sequence.

You can interrupt the sequence by pressing any key on the keyboard.

2.

Count-up (AUTO) mode:

When A is displayed, the unit will keep firing as long as you maintain
the TEST button pressed, or the "X" synchro signal. The display counts
up until you stop firing, then resets itself, ready for a new sequence.

Cell

"X"

X

100 - 240 V   50/60 Hz

TEST

10 A Slo. 220 V
20 A Slo. 110 V

Photo Cell/Beeper Conrols

Sequence Control

Содержание CONCEPT P4

Страница 1: ...A B C D MADE IN FRANCE 100 240 V 50 60 Hz TEST 10 A Slo 220 V 20 A Slo 110 V A CONCEPT P4 Auto Auto Max 100 ind X B C D Rue des Coutures Z I Sud de Torcy 77200 TORCY FRANCE Tel 33 0 1 64 11 63 90 Fax 33 0 1 64 11 63 91 99500 CP4 instructions ...

Страница 2: ...ERE ARE ABSOLUTELY NO USER SERVICEABLE PARTS INSIDE THE CONCEPT P4 Never open the unit and never attempt to repair it You might be injured by the high voltage BALCAR maintains repair stations around the world to give you the best service 2 ALWAYS DISCHARGE and UNPLUG the light heads before removing the Pyrex shell and touching the flashtube or the model lamp 3 NEVER use fuses rated higher than tho...

Страница 3: ...l Lamp Selector When pressed normally changes model lamp modes model lamps off no mode selected Auto Each model lamp is proportional to the flash power of each head 10 is 100 9 is 50 8 is 25 etc Auto Max Each model lamp is proportional to the flash power of each head but there is always one model lamp at 100 the other model lamps are proportionally lower 100 independent The level of each model lam...

Страница 4: ...rovided with your unit The CONCEPT P4 is powered by turning the ON OFF switch of the A C plug assembly to the ON position This switch is also called the hardware on off because it actually cuts off the A C supply line when in the OFF position The 0 1 switch at the bottom left of the control panel is called the auxiliary on off It is used to actually turn the unit on or off after the hardware switc...

Страница 5: ...k the up key 5 times to 8 7 Power ratios between two heads are the difference between their displays For example if Head A is at 8 0 and Head B is at 9 5 the power ratio is 1 5 1 1 2 f stops the difference between 9 5 and 8 0 When using the Master Up or Down keys notice that all displays increment or decrement together therefore preserving the light ratio between each head as the difference betwee...

Страница 6: ...or switch at the back of each head is in an equivalent position 5 AUTO MAX mode This mode is identical to the AUTO mode but the intensity of the model lamp of the head at the highest flash power is set at 100 In order to preserve proportionality all other model lamp values are increased accordingly The following example summarizes the differences between each mode Head A B C Flash Power 8 0 6 5 9 ...

Страница 7: ... Cell The photocell is activated by pressing the Photo Cell button The yellow LED indicator is on when the cell is active 100 charge Audible Signal The 100 charge audible signal is activated by pressing the audible signal but ton The yellow LED indicator is on when the signal is active You can flash as soon as the audible signal starts Sequencer The CONCEPT P4 Sequencer is used to create multiple ...

Страница 8: ...he variators will not affect flash duration but will modify color temperature On the other hand using the power selector at the back of the head will change flash duration while maintain ing color temperature For shorter flash duration set the head at the lowest power setting using the head power selector We recommend adding a second flash tube in the cross position which reduces flash duration up...

Отзывы: