5.

MODEL LAMP CONTROL

Model Mode Selection

The CONCEPT P4 offers many model lamp modes which are selected using the
Model Lamp Mode button at the upper right of the control panel keypad.

Each time you press the button, the model mode changes, and the correspond-
ing yellow LED indicator lights up. When no LED's are on, you have selected the
OFF mode.

1.

OFF mode:
All model lamps are turned off.

2.

Ind (Independent) mode:
Each model lamp is lit at a specific level which you can modify. This is
explained below.

3.

100% mode:
All model lamps are set at 100% (10) power, regardless of the flash
power of each head.

4.

AUTO mode:
The model lamp level of each head is proportional to the actual flash
power of that head. For example, a head set at 10 will have a model
lamp level of 10 (100%). A head set at 8.0, will have a model lamp
level of 8.0 (25%).

True proportionality between flash and model lamp is only obtained if
the model lamp of each head is of the same type (i.e. all 150W or all
300W), and if the power selector switch at the back of each head is in
an equivalent position.

5.

AUTO MAX mode:
This mode is identical to the AUTO mode, but the intensity of the
model lamp of the head at the highest flash power is set at 100%. In
order to preserve proportionality, all other model lamp values are
increased accordingly.

The following example summarizes the differences between each
mode:

Head

A

B

C

Flash Power

8.0

6.5

9.0

Model Lamp Power

OFF

OFF

OFF

OFF

100%

10

10

10

ind.

8.0*

8.0*

8.0*

AUTO

8.0

6.5

9.0

AUTO MAX

9.0

7.5

10

* 8.0 is the default value, but you can change it to any value.

Model Mode Display/Independent Mode

By maintaining the Model Lamp Selector button pressed, the individual head
double-digit display will display the model lamp level for that head, until you
release the Model Lamp Selector. While still maintaining the Model Lamp
Selector button pressed, you can turn each model lamp on or off by pressing the
individual ON/OFF button of each head.

The individual model lamp yellow LED (to the immediate left of the individual
ON/OFF button) indicates whether that model lamp is on. Individual model
lamps cannot be turned on if the model lamp mode is OFF.

Model Mode Selection

Individual Display & Control

Amp

Auto

Auto Max

100%

ind

A

Содержание CONCEPT P4

Страница 1: ...A B C D MADE IN FRANCE 100 240 V 50 60 Hz TEST 10 A Slo 220 V 20 A Slo 110 V A CONCEPT P4 Auto Auto Max 100 ind X B C D Rue des Coutures Z I Sud de Torcy 77200 TORCY FRANCE Tel 33 0 1 64 11 63 90 Fax 33 0 1 64 11 63 91 99500 CP4 instructions ...

Страница 2: ...ERE ARE ABSOLUTELY NO USER SERVICEABLE PARTS INSIDE THE CONCEPT P4 Never open the unit and never attempt to repair it You might be injured by the high voltage BALCAR maintains repair stations around the world to give you the best service 2 ALWAYS DISCHARGE and UNPLUG the light heads before removing the Pyrex shell and touching the flashtube or the model lamp 3 NEVER use fuses rated higher than tho...

Страница 3: ...l Lamp Selector When pressed normally changes model lamp modes model lamps off no mode selected Auto Each model lamp is proportional to the flash power of each head 10 is 100 9 is 50 8 is 25 etc Auto Max Each model lamp is proportional to the flash power of each head but there is always one model lamp at 100 the other model lamps are proportionally lower 100 independent The level of each model lam...

Страница 4: ...rovided with your unit The CONCEPT P4 is powered by turning the ON OFF switch of the A C plug assembly to the ON position This switch is also called the hardware on off because it actually cuts off the A C supply line when in the OFF position The 0 1 switch at the bottom left of the control panel is called the auxiliary on off It is used to actually turn the unit on or off after the hardware switc...

Страница 5: ...k the up key 5 times to 8 7 Power ratios between two heads are the difference between their displays For example if Head A is at 8 0 and Head B is at 9 5 the power ratio is 1 5 1 1 2 f stops the difference between 9 5 and 8 0 When using the Master Up or Down keys notice that all displays increment or decrement together therefore preserving the light ratio between each head as the difference betwee...

Страница 6: ...or switch at the back of each head is in an equivalent position 5 AUTO MAX mode This mode is identical to the AUTO mode but the intensity of the model lamp of the head at the highest flash power is set at 100 In order to preserve proportionality all other model lamp values are increased accordingly The following example summarizes the differences between each mode Head A B C Flash Power 8 0 6 5 9 ...

Страница 7: ... Cell The photocell is activated by pressing the Photo Cell button The yellow LED indicator is on when the cell is active 100 charge Audible Signal The 100 charge audible signal is activated by pressing the audible signal but ton The yellow LED indicator is on when the signal is active You can flash as soon as the audible signal starts Sequencer The CONCEPT P4 Sequencer is used to create multiple ...

Страница 8: ...he variators will not affect flash duration but will modify color temperature On the other hand using the power selector at the back of the head will change flash duration while maintain ing color temperature For shorter flash duration set the head at the lowest power setting using the head power selector We recommend adding a second flash tube in the cross position which reduces flash duration up...

Отзывы: