background image

Manufactured under one or more of these patents. 

U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2, Canadian Patent: 2342614, 

Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
42281_A | Compatible with SpaTouch 1 & 2

4

03.17

Spa Status

Important information about spa operation can be 

seen on the Main Screen. Most features, including Set 

Temperature adjustment, can be accessed from this 

screen. The actual water temperature can be seen, 

and the Set Temperature can be adjusted (see page 

5). Time-of-Day, Ozone and Filter status is available, 

along with other messages and alerts. The selected 

Temperature Range is indicated in the upper left  

corner. The Spa Equipment Control Icon will spin  

if any pump is running. A Lock icon is visible if the 

panel or settings are locked. 

Note: After 30 minutes* the display will automatically 

go into sleep mode, which turns the display off. This 

is normal operation. Touch anywhere on the screen 

to wake the panel up. 

*The actual number of minutes can be customized. See page 20.

Music

Lights

Time

Filter Cycle 1 Running

Ozone Running

Clean-up Cycle

Wi-Fi Signal Indicator

Lock

Invert Screen

High Temperature Range

Heat

Set Temperature

Settings

Temperature

Scale (F/C)

Jets

Содержание SpaTouch2

Страница 1: ...UserGuide Balboa Water Group ...

Страница 2: ...Started 01 The Main Screen 02 Setting the Temperature The Spa Screen Common Buttons Common Buttons 03 04 04 04 Fill it up 05 Spa Behavior 06 Time of Day Adjusting Filtration Additional Settings Restricting Operation 07 08 09 10 Utilities Screen 12 Information 13 GFCI Test Feature General Messages Messages Warning 14 15 16 Settings Screen 04 11 Contents The SpaTouch2 Auxiliary Panel Heater related ...

Страница 3: ...of Balboa Water Group 42281_A Compatible with SpaTouch 1 2 3 03 17 SpaTouch GettingStarted Balboa Water Group BP Series Systems User Interface and Programming Reference The spaTouch Icon Driven panel is compatible with all BP systems that already support the TP800 and or the TP900 If this panel is used with a system that supports only the TP400 and or TP600 many screens will work correctly and the...

Страница 4: ...the Wi Fi link is connected Continued on next page Important information about spa operation can be seen on the Main Screen Most features including Set Temperature adjustment can be accessed from this screen The actual water temperature can be seen and the Set Temperature can be adjusted see page 5 Time of Day Ozone and Filter status is available along with other messages and alerts The selected T...

Страница 5: ...ssages will include the Call for Service text as it requires a ser vice technician to fix the problem If the panel is locked and a message alert appears you will be taken to the Lock Screen where you will need to Unlock the panel before you can clear the message Touching the Error Warning Re minder Info Icon on the Message Screen will take you to the System Information Screen to allow for trou ble...

Страница 6: ...u structure is done by touching the screen At the bottom of the screen at certain times an indicator may appear showing that a mes sage is waiting Touch this indicator to go to the Message Display Screen On that Screen some of the messages can be dismissed For more on theMessage Display Screen see pages 25 30 Most menu screens time out and revert to the main screen after 30 seconds of no activity ...

Страница 7: ... than one ON state so the icon will change to reflect the state of the equipment Below are some examples of 2 speed Pump indicators If the Spa has a Circ Pump a Circ Pump Icon will appear to indicate its activity but outside of Priming Mode the Circ Pump cannot be controlled directly One exception The Main Spa Light is not shown on the Spa Screen it is only shown and controlled on the Main Screen ...

Страница 8: ...ted by pressing the up arrow or decremented by pressing the down arrow When you see both the Back button and an Active Save button the Save button will Save while the Back button will Cancel If the screen times out due to no activity it will act like Cancel Exiting Screens The Back button is on every screen except the Main Screen the Priming Mode Screen are a Message Display Screen When you see on...

Страница 9: ...and pending All material copyright of Balboa Water Group 42281_A Compatible with SpaTouch 1 2 9 03 17 Common Buttons Page Left Page Right Page up Down If an Up or Down button is shown and pressed when on a page with a text list the list can be scrolled a page at a time If there is a right arrow at the bottom of the screen it takes you to the next page Page Up Page Down Cleanup Cycle Off Ozone On S...

Страница 10: ...incorporates two temperature range settings with independent set temperatures The specific range can be selected on the Settings screen and is visible on the Main Screen in the upper left corner of the display These ranges can be used for various reasons with a common use being a ready to use setting vs a vacation setting Each range maintains its own set temperature as programmed by the user This ...

Страница 11: ...the spa will maintain set temperature and heat as needed in Ready Mode without polling In Rest Mode the spa will only heat to set temper ature during programmed filter times even though the water is being filtered constantly when in 24HR circulation mode Heat Mode Ready vs Rest Ready in Rest Mode appears in the display if the spa is in Rest Mode and the Jets 1 Button is pressed When the heater pum...

Страница 12: ...nd on will help it to prime Do not do this more than 5 times If the pump s will not prime shut off the power to the spa and call for service Important A pump should not be allowed to run without priming for more than 2 minutes Under NO circumstances should a pump be allowed to run without priming beyond the end of the 4 5 minute priming mode Doing so may cause damage to the pump and cause the syst...

Страница 13: ...on The specific Circulation Mode that is used has been determined by the Manufacturer and cannot be changed in the field Other device options may be available like Blower Light Mister etc Filtration and Ozone On non circ systems Pump 1 low and the ozone genera tor will run during filtration On circ systems the ozone will generally run with the circ pump but can be limited to filtration cycles On s...

Страница 14: ...e of Day is set Setting the time of day is important for determining filtra tion times and other background features The Heat Icon on the Settings Screen takes you to a screen where you control the Time of Day On the Time of Day screen simply select the Hours and Minutes Use the Up and Down Buttons to make changes then Save In the memory an Information Screen will appear If you exit it and Informa...

Страница 15: ...w Filter 2 Press 2 again to turn Filter 2 ON or OFF When Filter Cycle 2 is ON it can be adjusted in the same manner as Filter Cycle 1 It is possible to overlap Filter Cycle 1 and Filter Cycle 2 which will shorten overall filtration by the overlap amount Filter Cycle 2 is OFF by default Viewing Filter 1 while Filter 2 is OFF Viewing Filter 1 while Filter 2 is ON Adjusting Filtration Main Filtration...

Страница 16: ... with the start of the filter cycle If the Filter Cycle 1 duration is set for 24 hours enabling Filter Cycle 2 will initiate a purge when Filter Cycle 2 is programmed to begin The Meaning of Filter Cycles 1 The heating pump always runs during the filter cycle 2 In Rest Mode heating only occurs during the filter cycle 3 Purges happen at the start of each filter cycle For example if your spa is set ...

Страница 17: ... press the word Lock for at least 5 seconds To unlock either Settings or Panel first select Settings if it says Locked or Panel if it says Locked than press the word Lock for at least 5 seconds The control can be restricted to prevent unwanted use or temperature adjustments Locking the Panel prevents the controller from being used but all automatic functions are still active Locking the Settings a...

Страница 18: ...de is used to disable the pumps during service func tions like cleaning or replacing the filter Hold Mode will last for 1 hour unless the mode is exited manually If spa service will require more than an hour it may be best to simply shut down power to the spa The Hold Icon on the Settings Screen places the spa in Hold Mode and displays the System Hold screen Touch Back to exit Hold Mode Drain Mode...

Страница 19: ...onstrate the various features of a particular hot tub Fault Log The Fault Log is a record of the last 24 faults that can be reviewed by a service tech Use the Up and Down buttons to view each of the Faults When Priming Mode shows in the Fault Log it is not a fault Rather it is used to keep track of spa restarts GFCI Test Feature not available on CE rated systems Your systems may have GFCI configur...

Страница 20: ...ble set the length of time Pump 1 will run after each use 0 4 hours are available Settings it to 0 0 Hr keeps the Cleanup Cycles from running The Cleanup Icon on the Settings Screen takes you to the Cleanup Cycle screen Cleanup Cycle The Language Icon on the Settings Screen takes you to the Language screen Change the language displayed on the panel Reminders The Reminder Icon on the Settings Scree...

Страница 21: ...tem Model Displays the Model Number of the System Panel Version Displays a number of the software in the topside control panel Software ID SSID Displays the software ID number for the System Configuration Signature Displays the checksum for the system configuration file Current Setup Displays the currently selected Configuration Setup Number Dip Switch Settings Displays a number that represents th...

Страница 22: ... an RCD Test Feature due to the nature of the electrical service Some UL registered systems do not have the GFCI Test Feature activated The end user must be trained how to properly test and reset the RCD Only use the Reset Button prior to moving the spa to a new location Pressing the Reset the button forces a new Test to be performed at the new location The installer can cause the GFCI Trip Test t...

Страница 23: ...ted or the Aux Freeze Switch has closed All water devices are activated In some cases pumps may turn on and off and the heater may operate during Freeze Protection This is an operational message not an error indication The water is too hot M029 The system has detected a spa water temp of 110 F 43 3 C or more and spa functions are disabled System will auto re set when the spa water temp is below 10...

Страница 24: ...t The spa is shut down for 15 min Reset this message to reset the heater start up See Flow Related Checks below The heater is dry M027 There is not enough water in the heater to start it The spa is shut down After the problem has been resolved you must reset the message to restart heater start up See Flow Related Checks below The heater is too hot M030 One of the water temp sensors has detected 11...

Страница 25: ... are out of sync Call for service M026 The temperature sensors ARE out of sync The fault above has been established for at least 1 hour Call for Service Sensor A Fault Senor B Fault Sensor A M031 Sensor B M032 A temperature sensor or sensor circuit has failed Call for Service Communications error The control panel is not receiving communication from the System Call for Service Test software instal...

Страница 26: ...rs on more than one power up The clock has failed M020 Contact your dealer or service organization Configuration error Spa will not Start Up Contact your dealer or service organization The GFCI test failed System Could Not Test the GFCI M036 North America Only May indicate an unsafe installation Contact your dealer or service organization A pump may be stuck on M034 Water may be overheated POWER D...

Страница 27: ...fety device and must be tested on a regular basis to verify its reliability Every user should be trained to safely test the GFCI or RCD associated with the hot tub installation A GFCI or RCD will have a TEST and RESET button on it that allows a user to verify proper function Change the water May appear on a regular schedule i e every 90 days Change the water in the spa on regular basis to maintain...

Страница 28: ...tempt service of this control system Contact your dealer or service organization for assistance Follow all owner s manual power connection instructions Installation must be performed by a licensed electrician and all grounding connections must be properly installed CSA Compliance Conformité Caution Test the ground fault circuit interrupter before each use of the spa Read the instruction manual Ade...

Отзывы: