Pumps
On the Spa Screen, select a “Jets” button once to turn the
pump on or off, and to shift between low- and high-speeds
if equipped. If left running, the pump will turn off after a
time-out period.
Non-Circ Systems
The low-speed of pump 1 runs when the blower or any other
pump is on. If the spa is in Ready Mode (See page 11), Pump 1
low may also activate for at least 1 minute every 30 minutes
to detect the spa temperature (polling) and then to heat
to the set temperature if needed. When the low-speed turns
on automatically, it cannot be deactivated from the panel,
however the high speed may be started.
Circulation Pump Modes
If the system is equipped with a circ pump, it will be
configured to work in one of three different ways:
1. The circ pump operates continuously (24 hours) with the
exception of turning off for 30 minutes at a time when
the water temperature reaches 3°F (1.5°C) above the set
temperature (most likely to happen in very hot climates).
2. The circ pump stays on continuously, regardless of water
temperature.
3. A programmable circ pump will come on when the system
is checking temperature (polling), during filter cycles,
during freeze conditions, or when another pump is on.
The specific Circulation Mode that is used has been
determined by the Manufacturer and cannot be changed
in the field.
Other device options may be available, like Blower, Light,
Mister, etc.
Filtration and Ozone
On non-circ systems, Pump 1 low and the ozone genera-
tor will run during filtration. On circ systems, the ozone
will generally run with the circ pump, but can be limited to
filtration cycles. (On some circs systems, Pump 1 low will run
along with the circ Pump during filtration.)
The system is factory-programmed with one filter cycle that
will run in the evening (assuming the time-of-day is prop-
erly set) when energy rates are often lower. The filter time
and duration are programmable. A second filter cycle can be
enabled as needed.
At the start of each filter cycle, the water devices like
blower, mister device (if these exist) and other pumps will
run briefly to purge the plumbing to maintain good water
quality.
Freeze Protection
If the temperature sensors within the heater detect a low
enough temperature, then the water devices automatically
activate to provide freeze protection. The water devices
will run either continuously or periodically depending on
conditions.
In colder climates, an optional freeze sensor may be added
to protect against freeze conditions that may not be sensed
by the standard sensors. Auxiliary freeze sensor protec-
tion acts similarly except with the temperature thresholds
determined by the switch. See your dealer for details.
Clean-up Cycle (optional)
When a pump or blower is turned on by a button press, a
clean-up cycle begins 30 minutes after the pump or blower
is turned off or times out. The pump and the ozone gen-
erator will run for 30 minutes or more, depending on the
system. On some systems, you can change this setting.