Genesis Blower

 

 
Electrical installation 

Note:

 All electrical work must be carried out by a qualified electrician according to national wiring rules. 

Electrical installations should not be done until the blower is completely installed in its location. 
Check the main voltage before connecting the blower. 
The blower is fitted with an electrical supply cord which is in compliance with European standards EN60335-2-60 
and has the following wire-colour coding: 
 

CLASS I CLASS 

II 

Earth:  

Yellow and Green 

Earth: Without 

earth 

cable 

Neutral: Blue 

Neutral: 

Blue 

Live:  

Brown 

Live: 

Brown 

 
The installation of the whole system must be done using a fixed wiring switch that has a contact separation of at 
least 3 mm. in each pole. If the single-speed blower is fitted to an external variable speed control box, the blower 
must run at high speed for at least 5 seconds. 
 
Note: If the thermal protection for the air-blower motor is activated, the blower will not restart until power from the 
system has been cut off and switched on again AFTER the blower has cooled to room temperature. 
 

Maintenance 

No special maintenance is required for the blower although the intake filter can be cleaned by dismantling the 
base of the blower: to do this, remove the two screws at the back of the blower. The ozone-generated version of 
the air blower is in accordance with the COSHH regulations EH38 Ozone: health hazards and precautionary 
measures. 
 
If the power-supply cord is damaged, it must only be replaced by the manufacturer, service agent or a similar 
qualified agent in order to avoid damage. 
 

Note 

Please see the touchpad manual for wire information. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание HydroAir Genesis

Страница 1: ...ause a cold air injection into the whirlpool or spa Installation The blower is suitable for mounting below whirlpools and spas It must be secured to the installation place by means of three screws fit...

Страница 2: ...east 3 mm in each pole If the single speed blower is fitted to an external variable speed control box the blower must run at high speed for at least 5 seconds Note If the thermal protection for the ai...

Страница 3: ...das Gebl se f r sp te re Inspektionen und Wartungsarbeiten zug nglich ist Installation Das Gebl se eignet sich f r eine Installation unter der Badewanne darf aber f r den Badenden nicht zug nglich sei...

Страница 4: ...hoher Drehzahl eingeschaltet werden und mindestens f r 5 Sekunden dieser Drehzahl laufen Achtung Wenn sich der thermische Schutzschalter des Gebl semotors ausgel st hat kann das Gebl se erst wieder a...

Страница 5: ...etien Installation Le blower peut tre install en dessous d une baignoire et doit tre fix l installation par le biais de trois vis qui seront ins r es dans les trois pieds en caoutchouc du blower La ba...

Страница 6: ...en version standard il est important que si une com mande de variation de vitesse est utilis e le d marrage se fasse en pleine puissance V max et ce pour une dur e minimum de 5 secondes Note Veuillez...

Страница 7: ...rk Bl seren skal installeres et sted som muligg r fremtidige eftersyn og vedligeholdelse Installation Bl seren er velegnet til montering under badekarret Den skal fikseres ved hj lp af 3 skruer som p...

Страница 8: ...Hvis en standardbl ser er tilkoblet en ekstern variabel kontrolboks skal bl seren k re med maksimum ydelse i min 5 sekunder Bem rk Hvis termosikringen i bl seren sl r fra vil bl seren ikke kunne gens...

Отзывы: