Configuration Notes
2 pumps – 8.0A max each = 16A
5.5 kW heater at 240V = 23A nominal
5.5 kW heater at 120V = 11.5A nominal
No A/V
On 32A service (40A breaker):
A5 ON (heater at 120V can run with both pumps on high)
A7 OFF & A10 OFF (heater at 240V cannot run with even one pump on high if other pump is on low)
On 40A service (50A breaker) or 48A service (60A breaker):
A5 ON
A7 ON & A10 ON (heater at 240V can run with all pumps on high)