![Balboa Water Group BP500 Скачать руководство пользователя страница 47](http://html2.mh-extra.com/html/balboa-water-group/bp500/bp500_troubleshooting-manual_3539156047.webp)
47
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
42211 C
Setup Changes with DIP Switch 1 ON - BP2500
TEST MENU ACCESS (S1, SWITCH 1 ON) SERVICE TECHNICIAN ONLY.
DANGER! HIGH VOLTAGE WILL BE ACCESSIBLE! SERVICE TECHNICIAN ONLY!
While the system is running, move DIP Switch 1 (on S1 on the Main circuit board) to ON.
The system will enter Test Mode.
Moving DIP Switch 1 to OFF will exit Test Mode.
SOFTWARE SETUPS (BP2500)
Under the TEST Menu, the Setup screen will allow changing the Setup from 1 to any number established by the
manufacturer. Changing the Setup may require wiring changes as well.
Set:
104°F
8:32 PM
Ozone
Filter 1
Spa
Shortcuts
Settings
Test
High Range
102°F
Ready in Rest Mode
Heating
`
ON
1
10
S1
Test
Back
Setup
A/B Temps
Fault Log
Timeouts
Temp Limit
1
`
Off
`
Normal
Yes
Note:
For complete variations of equipment configurations and setups, the latest Tech Sheet should be obtained on the
system you're working on. The information for setup changes is included here in the event you have wiring diagrams available,
and to facilitate a better understanding of how setup changes are made.