![Balboa Water Group BP500 Скачать руководство пользователя страница 34](http://html2.mh-extra.com/html/balboa-water-group/bp500/bp500_troubleshooting-manual_3539156034.webp)
34
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
6/22/13
Troubleshooting Heater Resistance
TROUBLESHOOTING HEATER RESISTANCE
Locate the heater connector.
Disconnect the connector by depressing the tab.
Pull the connector straight out.
Place the meter probes on the heater terminals.
Release tab
Release tab
ACCEPTABLE HEATER OHM (
ȍ
) RANGES
Heater Type
Ohms (
1
)
5.5 kW @ 240 V
9.42
1
-11.52
1
4 kW @ 240 V
12.96
1
-15.84
1
1 kW @ 120 V
12.96
1
- 15.84
1
**Note: 1 k
1
= 1000
1
:
k
1
may vary +/- 10% depending on the accuracy of
the meter used.
TEST IS WITH POWER OFF