![Balboa Water Group BP500 Скачать руководство пользователя страница 29](http://html2.mh-extra.com/html/balboa-water-group/bp500/bp500_troubleshooting-manual_3539156029.webp)
29
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
42211 C
W
iri
ng Diagr
am - BP2000G
1,
Par
t Number 56377
-0
1 (
con
t.)
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
SWITCHBANK S1 OFF
SWITCHBANK S1 ON
PART B
BP2000G1 – PN 56377-01
01-29-13
USE EARTH GROUND CONNECTIONS AS INDICATED INSIDE THE SYSTEM ENCLOSURE
TOTAL OUTPUT AMP DRAW NOT TO EXCEED MAX INPUT RATING OF SPA
A DISCONNECTING MEANS MUST BE INSTALLED WITHIN SIGHT FROM
THE EQUIPMENT AND AT LEAST 5 FEET (1.52 M) FROM THE
INSIDE WALLS OF THE POOL, SPA, OR HOT TUB.
CONNECT ONLY TO CIRCUITS PROTECTED BY A CLASS A GFCI.
FOR SUPPLY CONNECTIONS, USE CONDUCTORS SIZED ON THE BASIS OF
60°C AMPACITY BUT RATED MINIMUM OF 90°C.
TORQUE RANGE FOR MAIN TERMINAL BLOCK (TB1): 27-30 IN. LBS. (31.1-34.5 kg cm)
USE COPPER CONDUCTORS ONLY. EMPLOYER UNIQUEMENT DES CONDUCTEURS DE CUIVRE. #6 AWG MIN. WIRE = 90°
1
NONE
2-SPEED
2-SPEED
2-SPEED
NONE
°F
2
NONE
2-SPEED
2-SPEED
1-SPEED
NONE
°F
3
NONE
2-SPEED
2-SPEED
NONE 1-SPEED °F
4
NONE
2-SPEED
2-SPEED
NONE NONE °F
5‡
NONE
2-SPEED
1-SPEED
1-SPEED
1-SPEED
°F
6
NONE
2-SPEED
1-SPEED
1-SPEED
NONE
°F
7
PROGRAMMABLE FILT POLLING
2-SPEED
2-SPEED
2-SPEED
NONE
°F
8
PROGRAMMABLE FILT POLLING
2-SPEED
2-SPEED
1-SPEED
NONE
°F
9
PROGRAMMABLE FILT POLLING
2-SPEED
2-SPEED
NONE
1-SPEED
°F
10
PROGRAMMABLE FILT POLLING
2-SPEED
2-SPEED
NONE
NONE
°F
11‡
PROGRAMMABLE FILT POLLING
2-SPEED
1-SPEED
1-SPEED
1-SPEED
°F
12‡
PROGRAMMABLE FILT POLLING
1-SPEED
1-SPEED
1-SPEED
1-SPEED
°F
13
PROGRAMMABLE FILT POLLING
2-SPEED
1-SPEED
1-SPEED
NONE
°F
14
PROGRAMMABLE FILT POLLING
1-SPEED
1-SPEED
1-SPEED
NONE
°F
15‡ NONE 2-SPEED
2-SPEED
1-SPEED
1-SPEED
°F
16‡
PROGRAMMABLE FILT POLLING
2-SPEED
2-SPEED
1-SPEED
1-SPEED
°F
17
PROGRAMMABLE FILT POLLING
1-SPEED
1-SPEED
NONE
1-SPEED
°F
18
NONE
2-SPEED
1-SPEED
NONE 1-SPEED °F
SETUP #
CIRC PUMP
PUMP 1
PUMP 2
PUMP 3
BLOWER
TEMP SCALE
* FOR 240V CIRC PUMP AND OZONE, CONNECT J20 TO J42 (IN GROUP 2)
INSTEAD OF
SETUP #1,
THIS SYSTEM IS
CONFIGURED IN
SETUP #:
PUMP 1 LOW TIMEOUT IS 15 MINUTES.
‡SETUPS 5, 11, 12, 15 AND 16 REQUIRE BP2X-WIRE KIT PN30893
LOCATION DEVICE
VOLTS
MAX
AMPS
FROM
TO
J9
PUMP 1
240V
12A MAX
J46
J72-GROUP 2
J14
AUX
240V
12A MAX
J18
J3-GROUP 2
AUX LINE 1 CONNECTION
J19
J43
J15 SPA
LIGHT
12V
1A
J21
CIRC PUMP
120V*
2A MAX
J20
J79-GROUP 4
J32 OZONE
1A
CIRC AND OZONE LINE 1 CONNECTION
J81
J59
J33
TV / AV
120V
3A
J38
J45-GROUP 4
J44 HEATER 240V
5.5
kW
TO
J1 ON
EXPANDER
TO RED AC (GROUP 2)
ON MAIN BOARD
SPLITTER OPTIONS:
IN SETUPS 5, 11, 12 S1 = PUMP 2 S3 = PUMP 3
IN SETUPS 15, 16 S1 = PUMP 3 S3 = FUSED ADAPTER
SPLITTER IS UNUSED (REMOVED) IN SETUPS 1-4, 6-10, 13, 14, 17, 18
SETUPS 15 AND 16 REQUIRE THE ADDITIONAL FUSED ADAPTER FOR BLOWER OUTPUT
WHITE
RED
WHITE
GREEN
GREEN
BLACK
S1
12A MAX
S2
12A MAX
FUSED ADAPTER
‡ OPTIONAL BP2X-WIRE KIT PN 30893
TO S2
SETUPS
15 & 16 ONLY
BLOWER
10A
TEST MODE OFF
DON’T ADD 1 HS PUMP W/HTR
DON’T ADD 2 HS PUMPS W/HTR
DON’T ADD 4 HS PUMPS W/HTR
SPECIAL AMPERAGE RULE A
STORE SETTINGS**
1 MIN HTR COOLDOWN (ELEC)
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
TEST MODE ON
ADD 1 HS PUMP WITH HEAT
ADD 2 HS PUMPS WITH HEAT
ADD 4 HS PUMPS WITH HEAT
SPECIAL AMPERAGE RULE A
MEMORY RESET**
5 MIN HTR COOLDOWN (GAS)
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
** SWITCH #
6
SHOULD BE SET TO OFF UPON FINAL INSTALLATION.