Page 6
54775_97_C
Wiring Configuration and DIP Settings
Setup 2
Switchbank A
Switchbank B
B2, Assignable
B3, Assignable
B4, Assignable
B5, Assignable
B6, Assignable
A5, Assignable
A6, Assignable
B1, Assignable
B8, Assignable
B9, Assignable
B10, Assignable
B11, Assignable
B12, Assignable
B7, Assignable
A8, Assignable
A9, Assignable
A7, Assignable
A11, Special Amp Rule OFF
A12, Memory ON
100
134
32
SSID #
1
2
3
1
2
3
3
2
1
3
2
1
3
2
1
J91
J91
J83
Config Settings
Enabled
RTC
Enabled
Spa Light
12V
J37
J2 with
Pump 1 Low
J39
J9
Black AC
J29
120V/240V
Fiber Light
and Wheel
J49
J47
B3, Not Assigned
B4, Not Assigned
B5, Not Assigned
B6, Not Assigned
B8, Not Assigned
B9, Not Assigned
B10, Not Assigned
B11, Not Assigned
B12, Not Assigned
B7, Not Assigned
A9, See Table 3
A6,
A5,
A8,
A7,
}
See Table 1
Circ Behavior
B2,
B1, See Table 3
AX40 - J1, J2, J3, J4
See Table 2
Blower
}
A3, + 2 Pumps w/Heat
120 Volt Connections
240 Volt Connections
Black AC Jumpers
12 Volt Connections
Relay Control Wires
Wiring Color Key
Typically Line voltage
Typically Line voltage for 2-speed pumps
Neutral (Common)
Ground
Note flat sides in connector
1
2
3
4
Board Connector Key
WARNING:
Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING:
Persistent Memory (A12) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)
WHT AC (120V)
B
LK A
C
RED AC (240V)
J66
J65 J68
J64
J63 J67
J58
J57 J62
J54
J59
J60 J56
J61
J74
J75 J53
J95
J46
J55
J44
J52
J28
J27
J35 J43 J23 J32
TB1
FUSE 30A CLASS G
F
U
S
E 30A
C
LA
SS
G
F6
F7
K7
HTR2
HTR1
K6
K8
FUSE 1/2A 250V
F2
K4
K3
K2
J37
K16
J7
J8
K11
K9
K10
G
N
G
N
G
N
J9
J11
G
N
J1
G
N
G
N
J12
G
N
G
N
G
N
G
N
J2
J3
J4
J5
J6
J49
J47
BLK-A
B
LK-A
J39
K5
K13
K1
K14
W5
W4
W30
W14
W10
W6
W7
W8
W12
W9
W13
W15
W2
W1
W3
BARCODE
SWITCHBANK A
SWITCHBANK B
J17
J84
J15
J83
J22
K12
K15
J86
J92
J85
F1
J24
J82
TST
AUX. F
CFG
SEN. A
SE
SEN. B
E
VAC
J21
TV 1
TV 2
J36
TRC6
J19
J18
UV
F5 FUSE 20A 250V
J90
J94
J76
J76
J14
J14
J93
J93
J79
J79
FUSE 3A 250V
F4
N
G
J10
U4
REMOTE
EXP I/O
DCM
J69
J20
J25
J38
J38
J81
J45
J4
1
J3
3
1
1
2
2
3
3
J29
1
1
2
2
3
3
12VAC-B
12V
AC-B
B
BLK-A
12VAC-B
1
2
3
J89
J26
J48
J50
J42
J77
MAIN P
ANEL
S
A
U
X P
ANEL
S
12 V
A
C
J16
J4
0
J34
J3
1
J73
J7
2
J7
1
J70
TORQUE
RANGE
FOR TB1:
27-30 IN. LBS.
H
OT
B
LA
C
K
NEUTRAL
WHIT
E
H
OT
RED
B
ALBOA INSTRUMENTS
, INC
.
E
L
8000
M
ac
h 3
C
OPYRIGHT 200
6
P/N 22041_
B
M
ADE IN
U
.S
.A.
G
N
J96
J96
J101
J100
J13
J97
J30
G
R
B
W
J1
W1
J2
J6
F30A 480V
X-P632
PN 53680
P/N 22909 REV B
1-Sp P4
5.5 kW
240V
Trans
Configuration
Settings
Enabled
RTC
Enabled
A.V
.
J91
J51
AD
C
d
D
J
C
d
J6
J3
J2
J1
TEST
Balboa
MADE IN U
.S
.A.
P/N 22039_
A
© 2006
120V Fiber
Fiber Opt.
Ozone
12V Light
Spa
Light
Circ.Pump
Blower
1-Spd P3
2-Spd P2
2-Spd P1
To TAG TV Lift #EXM17T
or similar continuity interfaced
TV Lift system.
s 60UMP3PEED
s 60UMP3PEED
s 60UMP3PEED
s 60UMP3PEEDON80
s 63PA,IGHT
s 6&IBERWWHEEL
s 6/ZONE
s 6!<63TEREO
s #ONTINUITY-OMENTARY46,IFT
s 6K7(EATER
s 6#IRC0UMPOPTIONAL
s 6"LOWEROPTIONAL
s -,-3-AIN0ANEL
s !$#-3PLITTER
s !80ANEL
Required for Jets 3 and
Jets 4 Buttons