Balboa Instruments EL8-EL84P-YCAH Скачать руководство пользователя страница 19

Page 19

54775_97_C

Panel Configurations

AX40 (Optional on Setup 1 – REQUIRED on Setup 2)
PN 55487 with Overlay PN 11823

s

 Connects to Aux Panel terminal J31, J34, J40, or J16

AX10A3 (Optional on Setup 1)
PN 52765 with  
Overlay PN 40107_B

s

 Connects to Aux Panel terminal 

  J31, J34, J40, or J16

ptional on Setup 1

REQUIRED on Setup 2)

Jets 1

Jets 4

Jets 3

Jets 1

Jets 2

Jets 4

AX10A3 (Optional on Se

Jets 1

Jets 1

Blower

Blower

Jets 3

Jets 1

Invert

Fiber

Jets 3

Time

Warm

Jets 1

Jets 2

Jets 3

Cool

Mode/Prog

Invert

Fiber

Light

F2

TL

F1

PL

Jets 4

Option

J1

J2

BL

LT

HT

FC

OZ

Select

Jets 2

Jets 1

Light

Blower

102º F

ML900
PN 54589 with Overlay PN 11806

s

 Connects to Main Panel terminal J70, J71, J72, or J73

MLM990S
PN 54527-02 with Overlay PN 11810

s

 Connects to ADCM Splitter

Note: RTC jumper (J91) on Main PCBA must be OFF (1 pin only)

S

ETUPS

 1

S

ETUP

 2

A

UXILIAR

Y

Содержание EL8-EL84P-YCAH

Страница 1: ...756 Base PCBA PN 55889 PCB EL8000 PN 22041 Rev A HEX File 10013432_EL84P_02 hex Configuration Signature 513BFF57 Base Panels ML900 PN 54589 Aux Panels AX10A3 PN 52765 Optional Base Panel MLM990S PN 54...

Страница 2: ...54775 2756 02 11 2008 Balboa New system at v31 54775 2756 04 24 2008 Balboa Update to v32 54775 2756 06 04 2008 Balboa Pages 1 19 AX40 panel PN 55487 54775 2756 09 10 2008 Balboa New Con g le Change...

Страница 3: ...O ADCM J69 J20 J38 1 2 3 LK A 12VAC B J77 MAIN PANELS AUX PANELS J16 J40 J34 J31 J73 J72 J71 J70 Power Requirements s 6 Z LASS PROTECTED SERVICE IRCUIT REAKER RATING MAX s WIRES HOT HOT NEUTRAL GROUND...

Страница 4: ...ration problem For example s would mean that the combination of how you ve set A5 and how you ve set B2 is not supported on this system s would mean that there is a problem with jumper J99 s would mea...

Страница 5: ...em Wiring Configuration and DIP Settings Setup 1 As Manufactured Switchbank A Switchbank B B2 Assignable B3 Assignable B4 Assignable B5 Assignable B6 Assignable A5 Assignable A6 Assignable B1 Assignab...

Страница 6: ...J75 J53 J95 J46 J55 J44 J52 J28 J27 J35 J43 J23 J32 TB1 FUSE 30A CLASS G FUSE 30A CLASS G F6 F7 K7 HTR2 HTR1 K6 K8 FUSE 1 2A 250V F2 K4 K3 K2 J37 K16 J7 J8 K11 K9 K10 G N G N G N J9 J11 G N J1 G N G N...

Страница 7: ...ump or blower is turned on Note A2 A3 A4 all off No heat with any high speed pump or blower CFE errors are illegal configurations such as a pump and a blower set to run on the same output The configur...

Страница 8: ...0 240 Volts AC Jumper on Pins 2 and 3 will power J8 pin 2 Fiber Optic Light at 12 Volts AC Note J47 and J49 must be set for the same voltage W5 controls voltage on return line of J8 pin 3 and must be...

Страница 9: ...bove 1 4 number of hours 3 DIP Switch Light Timeout d 1 2 3 4 d Use Timeouts value above 1 4 number of hours Scrunch Panel n Y n Normal panel layout Y Alternate panel layout ML900 scrunching enabled M...

Страница 10: ...ght and EitherLight buttons spa light enabled on SpaLight buttons only Spa Light On Off n Y n Dimmable H M L Light Y On Off Light 1 DIP Switch Fiber Optics n Y n Disabled Y Light and Wheel Enabled 2 D...

Страница 11: ...tton 3 Bank B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 Aux Button 4 Bank B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 1 6 Assigns Pump Number Pump 1 Pump 2 etc b Blower g Spa Light F Fiber...

Страница 12: ...A b C d E F g H J L n o P r Filter 2 Start Hour Set 1 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r Filter 2 Duration Set 1 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r Standard Defaults 0 0 12 a...

Страница 13: ...ycle runs If 4d is set to 0 only the Day cycle runs If neither 3d nor 4d is set to 0 both the Day and Night cycles run Sets default for user preferences only applies when persistent memory is reset A1...

Страница 14: ...1 2 5 4 4 5 2 3 6 7 8 DOLPHIN REMOTE ROUND REMOTE Remote Button 1 Bank B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 Remote Button 2 Bank B 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 Remote B...

Страница 15: ...4 8 7 6 5 Time Warm Warm Mode e Cool ML90x Custom Buttons Enable n Y n Disabled Y Enabled 1 DIP Switch ML75x MX75x Custom Button 1 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 ML75x MX75x Custom Bu...

Страница 16: ...L55x Custom Button 1 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 ML55x Custom Button 2 1 2 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7 ML55x Custom Button 3 1 2 3 4 5 6 b g F E o t d P n A U r O H...

Страница 17: ...Blower off when 2nd high speed pump on Note DIP A11 must be ON to use Special Amperage Rule Heat Cool Feature n Y n Disabled Y Enabled 1 DIP Switch Color Kinetics n Y n Disabled Y Enabled ACD n Y n D...

Страница 18: ...The EL circuit board is factory configured to deliver a preset voltage 120V or 240V to the on board ozone connector J4 See the ratings table on the wiring diagram attached to the cover of the enclosur...

Страница 19: ...ts 1 Jets 4 Jets 3 Jets 1 Jets 2 Jets 4 AX10A3 Optional on Se Jets 1 Jets 1 Blower Blower Jets 3 Jets 1 Invert Fiber Jets 3 Time Warm Jets 1 Jets 2 Jets 3 Cool Mode Prog Invert Fiber Light F2 TL F1 PL...

Отзывы: