Page 18
54775_97_C
Ozone Connections
9
K10
G
N
G
N
J4
J5
J6
W8
W12
W9
W13
W15
J21
TRC6
F5
FUSE 10A 250V
J93
J79
FUSE 3A 250V
F4
N
G
J10
J81
J45
J41
J33
N
ELS
12 V
A
C
J16
Use this slot for the leftover Red conductor
Line - Black conductor
Balboa Ozone connector configuration for 120V 60Hz
Ground (Green) conductor
Flat sides of sockets as shown
Common - Install the White conductor here for 120V ozone
Use this slot for the leftover White conductor
Line - Black conductor
Balboa Ozone connector configuration for 240V 60Hz
Ground (Green) conductor
Common - Install the Red conductor here for 240V ozone
B
G
B
G
Use this slot for the leftover conductor
Line - Black conductor
Ground (Green) conductor
Common - Red for 240V or White for 120V ozone (See W13 wire)
W13 wire determines voltage
Ozone Connector Voltage:
The EL circuit board is factory configured to deliver a preset voltage (120V
or 240V) to the on-board ozone connector (J4). See the ratings table on the wiring diagram attached to
the cover of the enclosure for the configured voltage. For 240V output W13 connects to Red AC and for
120V output W13 connects to White AC.
The voltage to the ozone connector can be changed in the field if required. W13 just needs to be set for
the required voltage.
Balboa Ozone Generator:
If the board is set up to operate a 120V ozone generator, the connector on the
ozone generator is likely to be configured correctly, but should be compared to the illustration below.
If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the
connector next to the green ground wire as described below.
Note: A special tool is required to remove the pins from the connector body once they are snapped in
place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool.