background image

COUNTERTOP GAS DECK OVEN OPERATION MANUAL

Models: 
GP-51 and GP-61

COUNTERTOP GAS DECK OVENS

All gas operated Bakers Pride

®

 deck ovens are intended 

for use with the type of gas specified on the rating plate 
and for installation will be in accordance with National 
Fuel Gas Code ANSI Z223.1 (latest edition).

Please retain this manual for future references.

This equipment is design engineered for commercial 
use only.

FOR YOUR SAFETY: Do not store or use gasoline 
or other flammable vapors or liquids in the vicinity 
of this or any other appliance. 

WARNING

Improper installation, adjustment, alteration, 
service or maintenance can cause property 
damage, injury or death. Read the installation, 
operating and maintenance instructions 
thoroughly before installing or servicing this 
equipment.

CAUTION

Instructions to be followed in the event the user 
smells gas must be posted in a prominent location 
in the kitchen area. This information shall be 
obtained from the local gas supplier.

NOTICE

BAKERS PRIDE

 

OVEN COMPANY, LLC.

1307 N. Watters Rd., Suite 180 

Allen, TX 75013

Phone: 800.527.2100  |  Fax: 914.576.0605  |  www.bakerspride.com

P/N U4128A REV B 10/19

IMPORTANT INSTRUCTIONS: After the gas 
supply has been connected to your unit, it is 
extremely important to check piping for possible 
leaks. To do this, use soap and water solution or 
solutions that are expressly made for this purpose. 
DO NOT USE matches, candles, flames, or other 
sources of ignition since these methods are 
extremely dangerous. Post in a prominent location 
instructions to be followed in the event you smell 
gas. Obtain these instructions from your local gas 
supplier. 

WARNING

Only Pizza or Bread can have direct contact with 
Fibrament decks. All other food products must 
be placed in a pan or container to avoid direct 
contact with ceramic decks. 

NOTICE

California Residents Only
WARNING: This product can expose you to 
chemicals including chromium which is known to 
the State of California to cause cancer and birth 
defects or other reproductive harm. For more 
information go to www.P65Warnings.ca.gov. 

WARNING

Содержание GP Series

Страница 1: ...BUILT BY CRAFTSMEN TESTED BY TIME SERIES GP OPERATION MANUAL HEARTHBAKE SERIES COUNTERTOP GAS OVENS ...

Страница 2: ... shall be obtained from the local gas supplier NOTICE BAKERS PRIDE OVEN COMPANY LLC 1307 N Watters Rd Suite 180 Allen TX 75013 Phone 800 527 2100 Fax 914 576 0605 www bakerspride com P N U4128A REV B 10 19 IMPORTANT INSTRUCTIONS After the gas supply has been connected to your unit it is extremely important to check piping for possible leaks To do this use soap and water solution or solutions that ...

Страница 3: ...nt 8 Oven Interior 8 Baking Chamber 8 Baking Decks 9 Burner Compartment 9 Troubleshooting Chart 9 EXPLODED VIEWS PARTS LISTS GP 51 Parts List w Exploded Views 10 GP 61 Parts List w Exploded Views 13 WARRANTY 16 For European Communities EN 437 Gas Cat Gas and Supply Pressures Designated European Market u A T B E D K F I F R G R D E I E I T L U N L P T E S S E G B I2H G20 20mbar u u u u u u u u u I2...

Страница 4: ...ion Minimum Clearance from Left Side 2 51mm 2 51mm Minimum Clearance from Right Side 1 25mm 0 Minimum Clearance from Rear 5 127mm 2 51mm Set Up Your oven is packed in a carton and strapped to a skid Remove the oven and carton from the skid before unpacking Unpack carefully to avoid damage to the oven If concealed damage is found follow the instructions detailed in Section 1 Keep the area around th...

Страница 5: ... the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 in the USA CAN CGA 6 16 in Canada and a quick disconnect device that complies with the latest edition of the Standard for Quick Disconnect Devices for use with gas fuel ANSI Z21 41 in the USA CAN CGA1 6 9 in Canada and adequate means must be provided to limit the movement of the appliance without depending on the connector and any...

Страница 6: ...ction in compliance with EN 60335 1 and or local codes c The ovens should not be installed on the same line with space heaters boilers or other gas equipment with high intermittent demand d Use a pipe joint compound that is resistant to the action of liquefied petroleum gases when making gas connections e For Propane gas use at least 1 2 13 mm pipe or tubing with a 5 8 16 mm inside diameter For Na...

Страница 7: ...ect Venting Optional Not Available For European Community Countries If direct venting it is necessary to install a draft hood fig 2 The flue pipe from the draft hood must not run downwards at any point from the oven to the final outlet It should always slant slightly upwards For best results it should rise straight up Do not put a damper in the flue and do not connect a blower directly to the flue...

Страница 8: ...e That indicates a good mixture of gas and air When using LP gas the flame will have a blue yellow appearance Should the Burner fail to light check to see if there is a problem with the gas supply If there are other appliances on the same line shut them off temporarily and see if the burner comes back on or it fluctuates as other gas appliances are turned on and off That would indicate overloading...

Страница 9: ...a pan When you determine the combination of method ingredients and temperature that gives the right bake for your crust sauce and cheese combination and your customer s taste mark and keep it Deck baking refers to baking Pizza directly on the deck Generally it is a thin product that requires temperature of at least 550 F 290 C Screen baking refers to baking Pizza on a screen The screen lifts the P...

Страница 10: ...gent solutions and cleaners that meet the national and or local codes Baking Chamber Clean the ceiling and the walls of the baking chamber with a mild soap and water solution Do not use oven cleaners caustic solutions or mechanical means as they will damage the interior aluminized surface e Bubbles in fresh dough indicate under proofed or cold product Allow the dough balls to proof to double in si...

Страница 11: ...not light Gas valve feeding oven may be in the closed position Turn gas valve on Relight pilot Thermopile may not be positioned in pilot flame Ensure that the tip of thermopile is in pilot flame Thermopile may be defective Call local authorized Bakers Pride Service Agent Oven too Hot Thermostat set too high Lower the thermostat setting and see if flame reduces in size Allow several hours for heat ...

Страница 12: ...COUNTERTOP GAS DECK OVEN OPERATION MANUAL 10 EXPLODED VIEWS PARTS LISTS Figure A GP 51 Exterior Deck Burner Compartment Rod Door Interior Trim ...

Страница 13: ...KS 34 S1023X 4 CASTERS W LOCKS Burner Compartment ITEM PART DESCRIPTION 35 A5258X UPPER BREATHER PAN 36 A5321K FLUE DEFLECTOR SET LEFT RIGHT 37 A5237X SLIDE OUT FLAME DIVERTER 38 A5341K INSULATION PAN SET TOP BOTTOM 39 A5301K COMBUSTION CHAMBER FRONT CENTER 40 A5302K BURNER ACCESS COVER 41 S3203X MAGNETIC LATCH ASSEMBLY Door Rod Accessories Intertior Trim ITEM PART DESCRIPTION 42 A5288X SPRING BRA...

Страница 14: ...BLANK SPUD 2 FOR 2 INSPIRATOR 69 M1296X THERMOCOUPLE T 46 USED W BGOR Figure B GP 51 Burner Figure C GP 51 Plumbing Control ITEM PART DESCRIPTION 70 M1392X CONTROL ASSY TO UNION N G BGOR 71 M1393X CONTROL ASSY TO UNION L P BGOR 72 M1005X THERMOSTAT 73 S1056X THERMOSTAT KNOB F 74 S1163X THERMOSTAT KNOB C 75 R3152X 7000 COMBO VALVE N G BGOR 76 R3154X 7000 COMBO VALVE L P BGOR 77 M1297X N G BGOR VALV...

Страница 15: ...COUNTERTOP GAS DECK OVEN OPERATION MANUAL 13 EXPLODED VIEWS PARTS LISTS Figure A2 GP 61 Exterior Deck Burner Compartment Rod Door Interior Trim ...

Страница 16: ...SLIDE OUT FLAME DIVERTER 38 A5259X INSULATION PAN SET TOP BOTTOM 39 A5251X COMBUSTION CHAMBER FRONT CENTER O S 40 A5252X BURNER ACCESS COVER O S 41 A5301K COMBUSTION CHAMBER FRONT CENTER 42 A5302K BURNER ACCESS COVER 43 S3203X MAGNETIC LATCH ASSEMBLY Door Rod Accessories Intertior Trim ITEM PART DESCRIPTION 44 A5288X SPRING BRACKET 45 A5291X LEFT DOOR STOP 46 A5292X RIGHT DOOR STOP 47 A5293X DOOR ...

Страница 17: ... GP 61 Burner Figure C2 GP 61 Plumbing Control ITEM PART DESCRIPTION 76 M1392X CONTROL ASSY TO UNION N G BGOR 77 M1393X CONTROL ASSY TO UNION L P BGOR 78 M1290X CONTROL ASSY TO UNION N G BMVR O S 79 M1291X CONTROL ASSY TO UNION L P BMVR O S 80 M1005X THERMOSTAT 81 S1056X THERMOSTAT KNOB F 82 S1163X THERMOSTAT KNOB C 83 R3152X 7000 VALVE BGOR N G AFTER SN339 8 98 84 R3154X 7000 VALVE BGOR L P AFTER...

Страница 18: ...adiants Stones and Valves are covered for a period of SIX MONTHS All Ceramic Baking Decks are covered for a period of THREE MONTHS The installation of these replacement decks is the responsibility of the purchaser The extended Cyclone door warranty years 3 through 5 is a parts only warranty and does not include labor travel mileage or any other charges EXCLUSIONS Negligence or acts of God Failures...

Страница 19: ...TANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment For Warranty Service and or Parts this information is required Model Number Serial Number Date Purchased ...

Страница 20: ...18 NOTES ...

Страница 21: ...19 NOTES ...

Страница 22: ...nnouncements and events on social media 1307 N Watters Rd Ste 180 Allen Texas 75013 Phone 800 527 2100 Fax 914 576 0605 bakerspride com 4 15 2019 Social icon Square Only use blue and or white For more details check out our Brand Guidelines ...

Отзывы: