background image

 

WHAT IS COVERED

This warranty covers defects in material and workmanship under normal use, and applies only to the original purchaser 
providing that:

The equipment has not been accidentally or intentionally damaged, altered or misused;

The equipment is properly installed, adjusted, operated and maintained in accordance with National and local codes. and 
in accordance with the installation instruction provided with the product;

The serial number rating plate affixed to the equipment has not been defaced or removed.

WHO IS COVERED

This warranty is extended to the original purchaser and applies only to equipment purchased for use in the U.S.A.

COVERAGE PERIOD

Full size gas and electric deck ovens: Two (2) year limited parts and labor: Cyclone Convection Ovens: BCO Models: One (1) 
Year limited parts and labor; GDCO Models: Two (2) Year limited parts and labor; CO II Models: Two (2) Year limited parts 
and labor; (5) Year limited door warranty.
All Other Products: One (1) Year limited parts and labor.
Warranty period begins the date of dealer invoice to customer or ninety (90) days after shipment date from BAKERS PRIDE - 
whichever comes first.

WARRANTY 

This  warranty  covers  on-site  labor,  parts  and  reasonable  travel  time  and  travel  expenses  of  the  authorized  service 

COVERAGE

representative up to (100) miles. round trip, and (2) hours travel time. The purchaser. however, shall be responsible for all 
expenses related to travel, including time. mileage and shipping expenses on smaller counter models that may be carried into 
a Factory Authorized Service Center, including the following models: PX-14. PX-16, PI8, and BK-I8.

EXCEPTIONS

All removable parts in BAKERS PRIDE Char-broilers, including but not limited to: Burners, Grates. Radiants, Stones and 
Valves, are covered for a period of SIX MONTHS.
All Ceramic Baking Decks are covered for a period of THREE MONTHS. The installation of these replacement decks is the 
responsibility of the purchaser.
The extended Cyclone door warranty years 3 through 5 is a parts only warranty and does not include labor, travel, milage or 
any other charges.

EXCLUSIONS

Negligence or acts of God,

Thermostat calibrations after (30) days from equipment
installation date,

Air and Gas adjustments,

Light bulbs,

Glass doors and door adjustments.

Fuses,

Char-broiler work decks and cutting boards,

Tightening of conveyor chains,

Adjustments to burner flames and cleaning of pilot burners,  

Tightening of screws or fasteners.

Failures caused by erratic voltages or gas supplies,

Unauthorized repair by anyone other than a BAKERS PRIDE

Factory Authorized Service Center,

Damage in shipment,

Alteration, misuse or improper installation,

Thermostats and safety valves with broken capillary tubes. 

Accessories - spatulas, forks. steak turners, grate lifters,
oven brushes, scrapers, peels. etc.,

Freight - other than normal UPS charges,

Ordinary wear and tear.

INSTALLATION

Leveling and installation of decks. as well as proper installation and check out of all new equipment - per appropriate 
installation and use materials - is the responsibility of the dealer or installer, not the manufacturer.

REPLACEMENT 

BAKERS PRIDE genuine Factory OEM parts receive a (90) day materials warranty effective from the date of installation by a 

PARTS

BAKERS PRIDE Factory Authorized Service Center.

This Warranty is in lieu of all other warranties, expressed or implied, and all other obligations or liabilities on the manufacturers part. BAKERS PRIDE 
shall in no event be liable for any special, indirect or consequential damages, or in any event for damages in excess of the purchase price of the unit. The 
repair or replacement of proven defective parts shall constitute a fulfillment of all obligations under the terms of this warranty.

BAKERS PRIDE LIMITED WARRANTY

30 Pine Street  New Rochelle, New York  10801

914 / 576 - 0200 

 US & Canada: 1 - 800 - 431 - 2745 

 fax 914 / 576 - 0605

Form #U4177A 1/07

16

Содержание GP-51 Series

Страница 1: ...lle NY 10801 914 576 0200 Phone 800 431 2745 US Canada 914 576 0605 Fax www bakerspride com WebAddress Note Only Pizza or Bread can have direct contact with ceramic decks All other food products must be placed in a pan or container to avoid direct contact with ceramic decks This equipment has been engineered to provide you with year round dependable service when used according to the instructions ...

Страница 2: ...also to furnish forms for the consignee s claim When the oven arrives it should consist of A carton containing your new oven Two for a stacked unit Installation must conform with local codes and or to the latest edition of the ANS Z 223 1 National Fuel Gas Code in USA CAN CGA B 149 1 or 2 Installation Code in Canada This appliance must be installed by a competent person in accordance with the rule...

Страница 3: ...ion and proper gas combustion is essential As a minimum observe the clearances detailed in Section 2 Provide adequate ventilation and make up air in accordance with local codes Fit the flue diverter See fig 1 and the flue transition piece into the rectangular opening located at top near the middle rear of the oven for installing the oven under a ventilation hood For Direct Venting Optional Draft H...

Страница 4: ...gas units are not available in the European Community Countries a The appliance when installed must be electrically grounded in accordance with local codes and or the latest edition of the National Electric CodeANSI NFPA70 in USA Canadian Electric Code CSA C22 2 in Canada b In Europe appliance must be connected by an earthing cable to all other units in the complete installation and thence to an i...

Страница 5: ... or a ULlisted vent cap at the end of the flue pipe Termination of the vent must be at least 2 feet above the highest part of the roof within 10 feet Ref American GasAssociation Catalog No Xh0474 7 MAIN BURNER SAFETY PILOT OPERATION The purpose of the safety pilot system is to lock the gas supply to the main burner at the combination valve if for any reason the pilot burner is not lit Oven should ...

Страница 6: ...iceAgency if you need help 9 THERMOSTAT CALIBRATION No attempt should be made to calibrate the thermostat because it is accurately calibrated and sealed by the manufacturer Contact an authorized ServiceAgency if you need help 10 HEAT BAFFLEASSEMBLY The Heat Baffle Assembly distributes the heat evenly below the baking deck It must be in good condition in order to be effective A damaged Heat Baffle ...

Страница 7: ...F 235 C to 500 F 260 C 4 RECOMMENDED OPERATING PROCEDURE It is very important that at the end of day s operation the gas cock dial of the Main Burner is turned to the pilot position leaving only the pilot burner ON overnight Preheating a Turn the gas cock dial of the main burner to the ON position b Preheat the oven for 1 to 1 hours at 50 F 10 C lower than your baking temperature Baking a When rea...

Страница 8: ...IOR Clean the oven interior only when the oven is cold Use only the detergent solutions and cleaners that meet the national and or local codes a BAKING CHAMBER Clean the ceiling and the walls of the baking chamber with a mild soap and water solution Do not use oven cleaners caustic solutions or mechanical means as they will damage the interior aluminized surface b BAKING DECKS The baking decks are...

Страница 9: ... Gas volume or gas pressure may be inadequate Thermostat or thermocouple may be defective Turn gas valve on Relight pilot Turn gas valve on Relight pilot Ensure that the tip of thermopile is in pilot flame Call local authorized Bakers Pride Service Agent Lower the thermostat setting and see if flame reduces in size Allow several hours for heat to regulate Call local authorized Bakers Pride Service...

Страница 10: ... 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 43 44 47 45 46 47 48 49 50 51 53 52 42 54 55 56 Figure A Exterior Decks Burner Compartment Door Rod Interior Trim Page 2 of 4 Note When ordering ALWAYS specify Part Model Serial and type of gas 9 05 27 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 40 39 38 37 36 35 34 33 32 31 30 29 28 26 25 24 23 22 21 45 44 41 54 55 43 47 47 56 49...

Страница 11: ...nstr Plate 29 U1172X Lighting Instruction Plate 13 S1149X Burner Door Handle w Screw 30 U1140X Minimum Clearance Plate 14 A4129X Control Door 31 U1044X Bakers Pride Name Plate 8 15 S1300X Top Door Handle w Screw 32 T8089X Leg Shelf 16 A5253X Door Handle Mount 33 S1022X 4 Casters w No Locks 17 A5330T Top Door 7 34 S1023X 4 Casters w Locks 35 A5258X Upper Breather Pan 39 A5301K Combustion Chamber Fr...

Страница 12: ...45X Pilot Orifice L P 63 R3036X S S Pilot Tubing 45 64 L5032X Inspirator 2 65 R3075X Spud Assembly 2 w o Orifice 66 R3177A Burner Orifice N G Drill 30 67 R3077X Burner Orifice L P Drill 48 68 R3080X Blank Spud 2 For 2 Inspirator 69 M1296X Thermocouple T 46 Used w BGOR 70 M1392X Control Assy To Union N G BGOR 71 M1393X Control Assy To Union L P BGOR 72 M1005X Thermostat 73 S1056X Thermostat Knob F ...

Страница 13: ...od Interior Trim Page 2 of 4 Note When ordering ALWAYS specify Part Model Serial and type of gas 9 05 GP 61 Counter Top Gas Oven 30 Pine Street New Rochelle New York 10801 914 576 0200 914 576 0605 1 800 431 2745 www bakerspride com fax US Canada web address BAKERS PRIDE 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 40 39 38 37 36 35 34 33 32 31 30 29 28 26 25 24 23 22 21 58 57 56 55 54 53 52...

Страница 14: ...4 18 A5286X Top Door 14 2 A5229X S S Top Door Cover 7 19 A5276X Burner Door 3 A5231X Left Outer S S Side 20 S1014A 4 Leg Adjustable 4 A5232X Right Outer S S Side 21 S1050Y 30 Leg Painted Gray 5 A5233X Back Outer S S 22 S1212Y 30 Leg S S 6 A5234X Top Outer S S 23 S1241X 16 Leg S S 7 A5225X Bottom Trim 24 R3087X Flue Adapter 6 8 A5226X Control Panel 25 R3002X Direct Vent Draft Flue 6 9 A5235X Top Tr...

Страница 15: ...fice 71 R3146X Burner Orifice N G Drill 30 72 R3091X Burner Orifice L P Drill 48 73 R3080X Blank Spud 2 For 2 Inspirator 74 M1296X Thermocouple T 46 Used w BGOR 75 M1265X Thermopile Used w BMVR 76 M1392X Control Assy To Union N G BGOR 77 M1393X Control Assy To Union L P BGOR 78 M1290X Control Assy To Union N G BMVR O S 79 M1291X Control Assy To Union L P BMVR O S 80 M1005X Thermostat 81 S1056X The...

Страница 16: ...iod of THREE MONTHS The installation of these replacement decks is the responsibility of the purchaser The extended Cyclone door warranty years 3 through 5 is a parts only warranty and does not include labor travel milage or any other charges EXCLUSIONS Negligence or acts of God Thermostat calibrations after 30 days from equipment installation date Air and Gas adjustments Light bulbs Glass doors a...

Отзывы: