IL FORNO CLASSICO OVEN DESIGN & INSTALLATION GUIDE
22
SINGLE OVENS WITH SIDE MOUNTED CONTROLS
When building your facade, provisions must be made for
accessing the following: (see sketch 15, page 23)
Front:
1. Push-pull rods (2)
2. Arched opening and lintel plate
3. Combustion chamber door
Left Side:
1. Hinged control access panel
2. Side service access panel (optional). Access to this
panel eases potential service access to the valve,
booster burner control, booster burner ignition
module and thermostat, however all components
maybe accessed though the side mounted hinged
controls access panel.
Rear:
1. Rear booster burner, flame sensor and igniter
- Provision should be considered for potential
service of these components. Following are 3
options:
A. Rear access panel (recommended).
B. Hinged or removable panel on the front of the
facade to allow the removal of flue cover and
inserts. This provides greater access for a
technician to service these components through
the front of the oven (see drawing below).
C. Through the arched bake chamber entrance
(difficult).
2. Electrical connection
3. Gas connection
4. Minimum clearance for Service Technician and/or
for safe operation
Ventilation, Air Supply And Fire Protection:
See instructions on pages 14-19.
Figure 14B: Option “B” Access To Booster Burner