IL FORNO CLASSICO OVEN DESIGN & INSTALLATION GUIDE
20
SINGLE OVENS WITH FRONT MOUNTED CONTROLS
When building your facade, provisions must be made for
accessing the following: (see sketch 14, page 20)
Front:
1. Hinged control access panel
2. Push-pull rods (2)
3. Arched opening and lintel plate
4. Combustion chamber door
Left Side:
1. Side service access panel (optional &
recommended). Access to this panel eases
potential service access to the valve, booster
burner control, booster burner ignition module
and thermostat. However all components maybe
accessed though front hinged controls access
panel (difficult).
Rear:
1. Rear booster burner, flame sensor and igniter
- Provision should be considered for potential
service of these components. Following are 3
options:
A. Rear access panel (recommended).
B. Hinged or removable panel on the front of the
facade to allow the removal of flue cover and
inserts. This provides greater access for a
technician to service these components through
the front of the oven (see drawing below).
C. Through the arched bake chamber entrance
(difficult).
2. Electrical connection
3. Gas connection
4. Minimum clearance for ServiceTechnician and/or
for safe operation
Ventilation, Air Supply And Fire Protection:
See instructions on pages 14-19.
Figure 13B: Option “B” Access To Booster Burner