background image

II. OPERATING INSTRUCTIONS

1. LIGHTING PROCEDURE:

2. BROILING PROCEDURE:

BROILER TOP GRATES MUST BE HOT ENOUGH TO MAKE BLACK CHAR-MARKS WHEN

STARTING TO BROIL.

3. MAINTENANCE:

(a) SERVICE:

See Section 6 of Installation Instructions.

Once the pilot burners are lit, the broiler may be turned ON or OFF by turning the control valves ON

or OFF as necessary.

Adequate pre-heating time is necessary for the food to release from the broiler and to cook

properly.Allow the unit to pre-heat for 45 minutes to 1 hour before broiling.

(a)

Do not press the juice out of the meat because that will cause dry products.

(b)

After broiling, allow the meat to sit covered on a heated platter for 2-5 minutes before

cutting. This will allow the juices to "Settle" and the product will be more moist.

(c)

Do not use forks or other sharp objects to poke holes in the meat. Do not cut the meat

as it cooks.

(d)

Thick pieces of meat require a longer broiling time with less flare-up. Reduce flare up

by trimming excess fat for a longer broiling time without burning.

(e)

Keep the unit clean. Food caught between the grate will not allow hot air to rise

around the product. This will result in uneven heating and increase the cooking time.

Shut off the main gas supply before attempting any maintenance on the unit. If required, contact

your Dealer, the Factory, or a local Service Company to obtain qualified maintenance and repairs.

8

All manuals and user guides at all-guides.com

Содержание Dante SGBR-2

Страница 1: ...R SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or Maintenance can cause property damage injury or death Read the Installation Operating and Maintenance Instructions thoroughly before installing or servicing this equipment P N U4010A 5 97 1 Model SGBR and GG Instruc...

Страница 2: ...NS PAGE 3 3 3 4 5 5 5 5 5 6 6 6 7 7 2 OPERATING INSTRUCTIONS TABLE OF CONTENTS 1 2 3 4 5 SECTION Additional Installation Requirements Installation with Casters 6 7 8 5 Warranty 12 2 All manuals and user guides at all guides com ...

Страница 3: ... National Electrical Code ANSI NFPA No 70 in USA Canadian Electrical Code CSA C22 2 in Canada Due to intense heat generated by radiation these broilers should be installed in noncombustible locations only including above the grate level RIGHT SIDE 0 0 0 The gas pressure regulator supplied must be installed at the gas inlet of each broiler Each regulator is adjusted to yield a manifold pressure of ...

Страница 4: ...nnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 45 kpa The broiler must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kpa Check to see that AIR MIXER CAPS on th...

Страница 5: ...s Do not use more than one layer as this will reduce the amount of heat reaching the top grates and could reduce the life of the bottom grates Place the Top Grates over the glo stones with the wavy ribs face up These grates are designed to give a minimum of meat to metal contact The top grates should be positioned so that the grease drains built into each rib carry excess fat to the grease chute T...

Страница 6: ...ed 5 With a screwdriver adjust the pilot valves to provide a 1 2 12 7 mm flame Turn clockwise to reduce or counter clockwise to increase the pilot burner 6 Turn right burner control valve ON to light burners on the right half of the unit and turn left burner control valve ON to light burners on the left side of the unit 7 8 To shut down the unit turn both burner control valves OFF Each burner has ...

Страница 7: ...structed for proper servicing and operation a Install the casters with wheel brakes on the front of the appliance b Installation should be made with a connector that complies with the latest edition of the Standard connectors for Movable Gas Appliances ANSI Z21 69 in USA CAN CGA 6 16 in Canada and a quick disconnect Device that complies with the latest edition of the Standard for Quick Disconnect ...

Страница 8: ...ow the meat to sit covered on a heated platter for 2 5 minutes before cutting This will allow the juices to Settle and the product will be more moist c Do not use forks or other sharp objects to poke holes in the meat Do not cut the meat as it cooks d Thick pieces of meat require a longer broiling time with less flare up Reduce flare up by trimming excess fat for a longer broiling time without bur...

Страница 9: ...grates Spread the Glo Stones evenly and add only the amount necessary for a single layer Periodically push all the Glo Stones to one side and inspect the bottom grates If necessary brush the grates with a wire brush If the grates are cracked broken or deteriorated they should be replaced All the burners should be checked at the same time as the bottom grates Grease build up on the burners should b...

Страница 10: ...W 10 BURNER AIR MIXER CAP PILOT BURNERS PILOT FLAME ADJUSTING SCREW MANIFOLD FIG 1 SGBR SERIES AIR MIXER CAP AND PILOT BURNERS BURNER VALVE BURNER ORIFICE HOLDER VALVE EXTENSION STRAIGHT VALVE HANDLE ORIFICE MANIFOLD VALVE EXTENSION CURVED 4 ILLUSTRATIONS All manuals and user guides at all guides com ...

Страница 11: ...FIG 5 GG SERIES FIG 6 SGBR SERIES 11 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 12: ...rratingplateaffixedtotheequipmenthasnotbeendefacedorremoved WHO IS COVERED This warranty is extended to the original purchaser and applies only to equipment purchased for use in the U S A COVERAGEPERIOD Cyclone Convection Ovens Two 2 Yearlimitedpartsandlabor 5 Yearlimiteddoorwarranty AllOtherProducts One 1 Yearlimitedpartsandlabor Warrantyperiodbeginsthedateofdealerinvoicetocustomerorninety 90 day...

Отзывы: