1. INSTALLATION INSTRUCTIONS
1. INSTALLATION:
USA,
In Canada,
2.ACCEPTABLE CLEARANCES:
MINIMUM CLEARANCE FROM NON-COMBUSTIBLE"CONSTRUCTION:
3. GAS CONNECTION:
(a)
In
installation of this broiler must conform with the latest edition of theAmerican
National Standard Z-223.1 National Fuel Gas Code and/or local codes.
installation must conform with the latest edition of CAN/CGA-B149.1 or 2 Installation
Code and/or local codes.
(b)
This broiler when installed, must be electrically grounded in accordance with local
codes, and/or the latest edition of the National Electrical Code ANSI/NFPA No. 70 in
USA(Canadian Electrical Code CSAC22.2 in Canada).
Due to intense heat generated by radiation, these broilers should be installed in noncombustible
locations only, including above the grate level.
RIGHT SIDE
0
0
0
The gas pressure regulator supplied must be installed at the gas inlet of each broiler. Each
regulator is adjusted to yield a manifold pressure of 5" water column (12.5 mbar) for Natural Gas or
10" water column (25 mbar) for Propane Gas. No pressure regulator is required for propane gas in
Canada.
Recommended minimum gas supply lines are listed below:
All GG Models
SGBR-1 thru SGBR-3
1" (25 mm)
SGBR-4 thru SGBR-9
LEFT SIDE
BACK
1" (25 mm)
1 1/2" (38 mm)
3