6. LIGHTING PROCEDURE:
a. GG Series
If any burner fails to light, turn the burner valves to "OFF", wait five minutes
and repeat the above procedure.
CAUTION: THE PILOT BURNERS WILL STAY LIT UNTIL THE MAIN GAS SUPPLY TO THE
UNIT IS TURNED "OFF".
WAITAT LEAST 5 MINUTES BEFOREATTEMPTING TO RELIGHT.
b. SGBR Series
If any burner fails to light, turn the valve to "OFF", wait five minutes and repeat
the above procedure.
There are two pilot burners and shut off valves, (except for model GG-2 which only has one) one for
the right half and another for the left half of the unit. To light the pilot burners:
1.
Turn all broiler valves to the "OFF" position.
2.
Open main gas shut off valve (supplied by customer)
3.
Allow air to bleed from the gas line through the pilot burners.
4.
Light the pilot burners using a lit taper through the open areas above the salamander
rack below the burners. The pilot burner can also be lit by using a lit taper from above
the burners before the top grates, bottom grates and glo-stones are installed.
5.
With a screwdriver adjust the pilot valves to provide a 1/2" (12.7 mm) flame.
Turn clockwise to reduce or counter clockwise to increase the pilot burner.
6.
Turn right burner control valve "ON" to light burners on the right half of the unit,
and turn left burner control valve "ON" to light burners on the left side of the unit.
7.
8.
To shut down the unit, turn both burner control valves "OFF".
Each burner has a standing pilot burner which must be lit before the burners can be lit. To light the
pilot burners:
1.
Turn all broiler valves to the off position.
2.
Open main gas shut off valve (supplied by customer).
3.
Allow air to bleed from the gas line through the pilot burners.
4.
Light the pilot burners using a lit taper through the open areas above the salamander
rack below the burners. The pilot burners can also be lit by using a lit taper from
above the burners before the top grates, bottom grates and glo-stones are installed.
5.
With a screwdriver, adjust the pilot valves to provide a 1/2" (12.7 mm) flame. Turn
clockwise to reduce or counter clockwise to increase the pilot burner.
6.
Turn each burner control valve "ON" to light burners.
7.
6