For units using Propane Gas, supply lines with less than 1/2D (12.7 mm) inside diameter
should not be used, even for a small unit.
NOTE: Be
sure plug is installed in the connection not being used.
Be sure to cap whichever side is not connected.
NOTE:
4. BURNERS:
On the GG Series, the gas may be connected either in the rear or the bottom of the unit.
On the SGBR Series the gas manifold extends out on each side near the front of the unit. Gas can
be connected from either side.
A shut-off valve in a readily accessible location must be mounted on the gas supply line
before the unit.
When making gas pipe connections, pipe joint compound resistant to the action ofJiquefied
petroleum gases should be used.
The broiler and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45
kpa).
The broiler must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psig (3.45 kpa).
Check to see thatAIR MIXER CAPS on the front of all burners are adjusted and tightened allowing
half the opening in the burner to show.
Install burners following the steps below:
Please note that the straight burner (without the arm) is installed on the extreme right side on
models GG-2, GG-4 and GG-6 (see figure 5 ).
On the model GG-8 which has two straight burners (without arms), install one burner to the
extreme right of the unit and the second straight burner to the left of the center divider.
On the SGBR Series, only straight burners are used.
4