WORKSTATION EXIT .................................................................................................... 22

 

HUMIDITY CONTROL ................................................................................................... 23

 

SCREENS ....................................................................................................................... 30

 

MAIN SCREEN ............................................................................................................ 30

 

LEFT AND RIGHT WORKSTATION MAIN MENUS .......................................................... 31

 

INVIVO

2

 INITIAL SETTINGS SCREEN ............................................................................ 32

 

ENVIRONMENT CONTROL ........................................................................................... 34

 

WORKSTATION OVERVIEW .......................................................................................... 35

 

WORKSTATION SWITCHING ........................................................................................ 36

 

WORKSTATION ENVIRONMENT CONTROL SCREENS OVERVIEW ................................. 36

 

DATA LOGS ................................................................................................................. 37

 

UTILITIES .................................................................................................................... 38

 

HYPOXIC CYCLE .......................................................................................................... 39

 

OXYGEN SENSOR CALIBRATION ................................................................................. 42

 

HELP / SETTINGS ........................................................................................................ 43

 

WARNINGS ................................................................................................................. 44

 

USB TREND LOG ............................................................................................................. 49

 

CLEANING AND SERVICE REQUIREMENTS ..................................................................... 50

 

SERVICE AND CLEANING OVERVIEW ........................................................................... 50

 

CLEANING PROCEDURE – DURING AND AFTER EACH USE .......................................... 51

 

CLEANING PROCEDURE – DEEP CLEAN WITH FRONT SCREENS REMOVED ................ 52

 

1 YEAR SERVICE ......................................................................................................... 55

 

TROUBLESHOOTING ....................................................................................................... 57

 

THE WORKSTATION WILL NOT SWITCH ON .................................................................. 57

 

THE CIRCUIT BREAKER TRIPS ..................................................................................... 57

 

LOW GAS PRESSURE .................................................................................................. 57

 

EXCESSIVE GAS USAGE .............................................................................................. 58

 

INTERNAL EQUIPMENT NOT POWERING UP ................................................................ 58

 

THE WORKSTATION IS ONLY PARTIALLY OPERATIONAL .............................................. 58

 

WARRANTY INFORMATION ............................................................................................. 59

 

DISPOSAL INFORMATION ............................................................................................... 60

 

CONTACT DETAILS ......................................................................................................... 61

 

 

 

Содержание InvivO2 1000

Страница 1: ...Affix Serial Number Sticker Here UserManual UM 038 InvivO2 1000 Dual Chamber Hypoxia Workstation InvivO2 1000...

Страница 2: ...NVIVO2 WORKSTATION 6 ENVIRONMENTAL OPERATING CONDITIONS 6 SERVICE REQUIREMENTS 7 ELECTRICAL SUPPLY REQUIREMENTS 7 GAS SUPPLY REQUIREMENTS 8 INVIVO2 1000 DUAL WORKSTATION OVERVIEW 9 FRONT VIEW 9 FRONT...

Страница 3: ...DATA LOGS 37 UTILITIES 38 HYPOXIC CYCLE 39 OXYGEN SENSOR CALIBRATION 42 HELP SETTINGS 43 WARNINGS 44 USB TREND LOG 49 CLEANING AND SERVICE REQUIREMENTS 50 SERVICE AND CLEANING OVERVIEW 50 CLEANING PR...

Страница 4: ...15 Glove port cap 20 Figure 16 Glove port cap stowage and locator 20 Figure 17 Glove port cap storage location inside workstation 21 Figure 18 Glove port cap 22 Figure 19 Glove Port Locator 22 Figure...

Страница 5: ...Warning 34 Screen 11 Workstation Overview 35 Screen 12 Workstation Not in Use 35 Screen 13 Trend Log 37 Screen 14 Utilities Menu 38 Screen 15 Hypoxic Cycle Menu Continuous Cycle On 39 Screen 16 Hypoxi...

Страница 6: ...LE OF TABLES Table 1 List of Symbols 5 Table 2 Electrical Service Requirements 7 Table 3 Fuse Ratings 7 Table 4 Standard Gases 8 Table 5 Additional gases for specific operating modes 8 Table 6 Setting...

Страница 7: ...2 Carbon Dioxide CO2 and Compressed Air O2 or 25 Oxygen in Nitrogen to achieve the desired atmosphere The user can select the Oxygen concentration from 0 1 to 20 9 and Carbon Dioxide concentrations fr...

Страница 8: ...r Over pressure could damage the workstation Only the gases specified in this user manual may be used All gas bottles must be adequately secured before connection to the workstation The maximum power...

Страница 9: ...ls on standards tested refer to the DoC Certificate WEEE This equipment must be disposed of in accordance with the Waste from Electrical and Electronic Equipment WEEE Directive This product must not b...

Страница 10: ...ference in which case the user will be required to correct the interference at his own expense Precautions The InvivO2 has been tested and approved to EN61010 1 61326 1 and 61326 2 6 This means that t...

Страница 11: ...r to this manual in all cases where this symbol appears in order to find out the nature of the Potential Hazard and actions to be taken in order to avoid the Hazard Warning this equipment contains hig...

Страница 12: ...d or relocated by a qualified engineer To arrange installation or relocation please contact your local distributor The mains appliance coupler and plug are the AC mains supply isolation device and mus...

Страница 13: ...uency for each of the InvivO2 1000 Dual workstations are Voltage Range Frequency Nominal Power Rated Current Rated Power 220 to 240 Vac 50 60Hz 360W 8 1A 1830W 110 to 120 Vac 50 60Hz 360W 14 3A 1600W...

Страница 14: ...mode 42 to 49psi 3 to 3 5 bar 25 Oxygen in Nitrogen O2 N2 Maximum of 25 Oxygen in Nitrogen Industrial or medical Air For oxygen levels between 17 and 23 42 to 49psi 3 to 3 5 bar Table 5 Additional gas...

Страница 15: ...the installation location INVIVO2 1000 DUAL WORKSTATION OVERVIEW Front View The InvivO2 Dual Workstation is shown below in Figure 3 Figure 3 InvivO2 Dual Workstation 1 Ezeeyin Glove Ports 2 Single Pl...

Страница 16: ...ure 5 InvivO2 Internal View from Right 1 Internal Light 2 Temperature and Humidity Sensor Housing 3 Internal interlock door 4 Internal sockets 5 Humidity Outlet Optional 6 Condensate plate 7 Universal...

Страница 17: ...Left Side View Figure 6 Left Side End Panel with Ultrasonic Humidity Option 1 Lid Service access only 2 Humidity water tank Optional 3 Side Panel Service access only 4 Cooling vent Do not obstruct 5...

Страница 18: ...ions Figure 8 Gas and Electrical Connections 1 Ventilation Holes 2 Ethernet Port For use with Remote Monitoring Option Only 3 Safety label 4 Rear panel Service access only See Service Requirements sec...

Страница 19: ...e interlock consists of 4 main components Interlock outer door Interlock inner door Interlock chamber Interlock floor tray The interlock is accessed by opening either the outer or inner door Operating...

Страница 20: ...e inner interlock doors can be opened at a time for transferring media or materials between the two workstation chambers the items should be loaded onto the interlock floor tray the inner door closed...

Страница 21: ...inner door backwards to open the interlock door Move the material from the interlock chamber into the workstation chamber The interlock floor tray will slide into the workstation to allow for easier...

Страница 22: ...al from the workstation chamber into the interlock chamber Close the interlock inner door by sliding the interlock inner door forwards Exit the workstation chamber via the Ezeeyin glove ports Open the...

Страница 23: ...is provided via the Ezeeyin glove ports and Ezee Sleeve The Ezee Sleeve consists of a gloveless gas tight sleeve and a cuff The Ezee Sleeve attaches to the glove port via two O rings Note The worksta...

Страница 24: ...zee Sleeve before inserting the hand and arm as shown in Figure 10 Figure 10 Compressed Ezee Sleeve for Entry Hold the desired Ezee Sleeve cuff with the opposite hand Support the Ezee Cuff push the ha...

Страница 25: ...ion should be continued until the maximum amount of external atmosphere has been removed from the Ezee Sleeve and the Ezee Sleeve exerts some pressure on the arm hand Figure 13 Ezee Sleeve before vacu...

Страница 26: ...Cap can require a reasonable amount of force This can be made easier by pushing the uppermost part of the Handle to first break the vacuum at the upper edge of the Cap seal Figure 15 Glove port cap T...

Страница 27: ...Page 21 of 61 Figure 17 Glove port cap storage location inside workstation Repeat the procedure for the other hand if both hands are entering the workstation chamber...

Страница 28: ...the Glove Port replace the cap using the location posts and graphic to orient the Cap correctly on the Glove Port Note Care should be taken to ensure that the Ezee Sleeve material does not become caug...

Страница 29: ...nto the workstation atmosphere The workstation allows the humidity to rise to a user defined maximum at which point it will start to strip the excess humidity away at a control accuracy of 6 One sache...

Страница 30: ...m the tank is then passed through a filter to ensure that there is no contamination of the water supply to ultrasonic nebuliser Water Tank The water tank is included as part of the ultrasonic humidity...

Страница 31: ...crews holding the water tank in place Figure 23 Water Tank Thumb Screw Once these are removed the water tank can be lowered in the end panel to expose the top of the tank then tilting the top forward...

Страница 32: ...Page 26 of 61 Figure 25 Water Tank tilted forward partially removed Figure 26 Water Tank top tube removal...

Страница 33: ...Page 27 of 61 Figure 27 Water Tank electrical connector Figure 28 Water Tank bottom lifted out...

Страница 34: ...s below the tube connector to avoid spillage as the tube is removed Figure 29 Water Tank bottom tube disconnection Re installation is carried out reversing the removal procedure Once the humidity syst...

Страница 35: ...below the dew point to allow for the humidity to condense on the plate Figure 30 Condensate Plate As this forms droplets these are then collected into a small reservoir in the end panel that will the...

Страница 36: ...3 Screen 3 Workstation Selection From this menu you will be able to access all of the features of both workstations Selecting the Left workstation will bring up Screen 4 Left Main Menu and selecting t...

Страница 37: ...Workstation Main Menus Screen 4 Left Main Menu Screen 5 Right Main Menu The arrows on either side of the menu indicate which workstation is being controlled Pressing the Hope icon will return to the...

Страница 38: ...ements Set Points High Alarm Levels Low Alarm Levels Table 6 Settings screen column functions Rows 2 3 and 4 can be changed by the user by pressing on the value and a pop up will appear for the new se...

Страница 39: ...midity option fitted then the humidity set point is can be adjusted in increments of 5 using the arrows The software will then allow the humidity to rise to this value and limit the maximum internal h...

Страница 40: ...ng use to monitor the current workstation conditions and gain access to all of the in use functions Screen 9 Environment Control Overview Pressing the home icon on the bottom right will bring up Scree...

Страница 41: ...s Screen 9 Icon 3 Workstation Overview Screen 11 Workstation Overview The environment control screens can be accessed by pressing the Left Workstation or Right Workstation buttons If only one side of...

Страница 42: ...overview of the screen flow for both sides of the workstation Note the Hypoxic control has only been shown for the left workstation but is available for both Right Workstation Left Workstation Atmosp...

Страница 43: ...shown at the top of the box The red horizontal lines show the current Alarm levels from the settings screen to easily see if there have been any deviations outside of the required operating parameters...

Страница 44: ...he light on off and the bar will adjust the brightness of the lights in the main work area This bar can either be slid into position or tapping on the setting required Icon 4 Internal Lights Control B...

Страница 45: ...een the steps that is not able to be set as it is dependent on the difference between the set points within the gas control software Pressing on any of the values will bring up a dialogue box to enter...

Страница 46: ...continuous cycle you are able to select up to 3 different set points with a time to remain at each and if you only want 2 set points to can set step 3 to 0 minutes and copy the set points from step 2...

Страница 47: ...dity Settings Within the Hypoxic Mixing cycles the workstation will maintain the temperature and humidity settings These settings are accessed from the button on Screen 15 or Screen 16 and operate in...

Страница 48: ...ation point and the ambient atmosphere for the high operation point The Atmospheric Oxygen level is set to 20 9 as default but this can be changed if required Once this setting is entered to the corre...

Страница 49: ...is pressed for 3 seconds Button 2 Internal Lights This will open a separate pop up shown in Icon 4 The icon on the left turns the light on off and the bar will adjust the brightness of the lights in...

Страница 50: ...ing the initial turn in or if the set point has been changed by more than 0 2 C The alarm can be dismissed by pressing the return arrow at the bottom right of the screen If the workstation still has n...

Страница 51: ...This can be dismissed by pressing the back arrow at the bottom right but it will appear again if the water level is still too low after 20 minutes If the water tank is re filled then the alarm will au...

Страница 52: ...ved for longer than 5 minutes as a reminder to replace it after the log files have been copied to a computer for analysis This alarm can be dismissed by pressing the back arrow at the bottom right of...

Страница 53: ...workstation to avoid excessive gas usage as it indicates an issue with the gas tightness of the workstation Screen 23 Gas Mix Time Limit Warning Screen The alarm can be dismissed by pressing the back...

Страница 54: ...e refer to the section for common problems and solutions Screen 24 Input Gas Pressure Alarm Alarm Purpose Alarm Buzzer Sound Temperature Alarm 1 second Pulse On Off Input Gas Pressure Alarm Continuous...

Страница 55: ...t point CH9 Chamber Temp Actual Chamber Temperature Measurement in C CH10 Water Tank Level For workstations with Ultrasonic Humidity this is the water level remaining in the Water Tank CH11 Interlock...

Страница 56: ...waste port bag Weekly End User Fill humidifier tanks Weekly End User Calibrate oxygen sensors Monthly End User Deep clean workstation 3 6 months End User Replace detox sachets Annually End User Qualif...

Страница 57: ...re permitted The use of UV light is prohibited in the workstation as it will cause permanent damage The use of UV Light within the Workstation will invalidate the warranty Cleaning procedure during an...

Страница 58: ...o active an audible alarm in all screens other than the main menu The following screen will appear to ensure that the glove port pneumatic connector is disconnected before the screen is removed Figure...

Страница 59: ...the workstation o Interlock side walls o Interlock ceiling o Interlock floor trays o Interlock outer door For all workstation components wipe with a paper towel soaked in an appropriate cleaning agent...

Страница 60: ...ation chamber Close the outer interlock doors Plug the workstation back in at the mains Switch the workstation on Go into the setting menu reinstall the front screen activate the seal and connect the...

Страница 61: ...es Service Instructions Follow the Deep Cleaning Preparation stage for both sides of the workstation Unscrew the 2 thumb screws retaining the ceiling panel in the workstation Figure 34 Ceiling Panel T...

Страница 62: ...humbscrews Remove the used sleeves from the front screen and dispose of them Figure 37 Gloveport Sleeves Follow the Deep Cleaning Cleaning instructions using the appropriate cleaning material in the s...

Страница 63: ...station to identify low input gas pressures The gas input pressure is set to low o Check the gas supply bottle pressure is set to the recommended levels defined in the Gas Supply Requirements section...

Страница 64: ...blem persists after the above have been carried out then please contact your distributor to assist in identifying the issue or to arrange a service engineer visit Internal Equipment not powering up If...

Страница 65: ...ARTICULAR PURPOSE THE IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY ARISING OUT OF A COURSE OF DEALING OR OF PERFORMANCE CUSTOM OR USAGE OF TRADE Ruskinn Technology Limited DOES NOT WARR...

Страница 66: ...household waste site Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment Alternatively please contact your local distributor for dis...

Страница 67: ...ruskinn com General enquiries ruskinnoffice ruskinn com Website www bakerruskinn com YouTube channel http www youtube com ruskinntechnology Ruskinn Technology Limited is a registered company in United...

Отзывы: