background image

4 | Baker Hughes 

© 2021 Baker Hughes Company. All rights reserved. 

 

 
 

 

WARNING 

 
BEFORE  installing,  using  or  carrying  out  any  maintenance  tasks  associated  with  this  instrument, 
READ THE INSTRUCTIONS CAREFULLY. 
 
These instruments have been designed, manufactured and tested in accordance with the essential 
safety requirements of the Ukranian standard for explosible atmospheres ACTY 7113, ACTY 7114 
& GOST 22782.5-78. 
 
 

Products  certified  as  flameproof  equipment  or  for  use  in  intrinsically  safe  installations 
MUST BE: 

 
a) Installed, put into service, used and maintained in compliance with national and local regulations 

and  in  accordance  with  the  recommendations  contained  in  the  relevant  standards  concerning 
potentially explosive atmospheres. 

b) Used only in situations that comply with the certification conditions shown in this document and 

after verification of their compatibility with the zone of intended use and the permitted maximum 
ambient temperature. 

c)  Installed,  put  into  service  and  maintained  by  qualified  and  competent  professionals  who  have 

undergone  suitable  training  for  instrumentation  used  in  areas  with  potentially  explosive 
atmospheres.

 Such trainings are not supported by Baker Hughes.

 

It is the end user's responsibility to: 

•  Verify material compatibility with the application 

•  Ensure  proper  use  of  fall  protection  when  working  at  heights,  per  Safe  Site  Work 

Practices 

•  Ensure use of proper Personal Protective Equipment 

•  Take  the  appropriate  actions  to  ensure  that  site  personnel  who  are  performing 

installation,  commissioning  and  maintenance  have  been  trained  in  proper  site 
procedures for working with and around equipment, per Safe Site Work Practices 

Baker  Hughes  reserves  the  right  to  discontinue  manufacture  of  any  product  or  change 
product materials, design, or specifications without 

notice. 

 
Under certain operating conditions, the use of damaged instruments could cause a degradation of 
the performances of the system which may lead to personal injury or death.  
 
Use only 

Baker Hughes Masoneilan

 replacement parts, which are provided by the manufacturer, to 

guarantee that the products comply with the essential safety requirements of the Ukranian standard 
mentioned above. 
 

 

 

 

Содержание Masoneilan 7700E

Страница 1: ...Baker Hughes Data Classification Public Masoneilan Type 7700EElectro Pneumatic Positioner with I P 4000 Converter Ukrainian UA TR Instruction Manual Rev A...

Страница 2: ...REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN...

Страница 3: ...Assembly of a 7700E Positioner on a Valve 7 7 Pneumatic Connection of Positioner 7700E 7 8 Electrical Connection Installation and Start Up 7 8 1 Conduit entry in flameproof application 8 8 2 Electrica...

Страница 4: ...y qualified and competent professionals who have undergone suitable training for instrumentation used in areas with potentially explosive atmospheres Such trainings are not supported by Baker Hughes I...

Страница 5: ...pneumatic signal Model 7700E electro pneumatic positioner can be used only on Varipak valve 28000 2 Numbering System Unique positioner 7700 E with I P 4000 module Different versions Housing material...

Страница 6: ...Pi 0 33 W Li 0 Ci 0 IP66 Warning Potential electrostatic charging hazard See instructions for safe use 5 Flameproof Marking and Electrical Safety Parameters The marking on the serial plate stamped on...

Страница 7: ...Series instruction manual Ref 30857 for more details 7 Pneumatic Connection of Positioner 7700E Make sure that the air supply pressure is suitable for the installation and for the instrument When usin...

Страница 8: ...y on the single NPT ANSI ASME B1 20 1 housing conduit connection The cable entry has to be suitable to the equipment operating zone IP 6X for zones 20 21 and 22 If an adaptor or reducer is needed it m...

Страница 9: ...allation for explosible atmosphere with d protection mode Intrinsically safe installation for explosible atmosphere with ia protection mode Note It is under the user responsibility to check the instal...

Страница 10: ...ke sure that the local conditions in the potentially explosive atmosphere permit the safe opening of the cover Connect the wires to the instrument s terminals taking care of complying with polarities...

Страница 11: ...ment are not damaged In the event of damage replace the defective parts with genuine manufacturer s replacement parts Pay particular attention to the following o General condition of the housing o Che...

Страница 12: ...vertical position uppermost the required ingress protection against water is invalidated therefore it shall only be installed in this orientation if its location provides protection against falling wa...

Страница 13: ...ss 123112 Russia Moscow Presnenskaya embankment house 10 room III floor 3 room 22 Tel 7 495 739 68 11 MoscowHelpDesk bakerhughes com 14 Design and Manufactured by Products are designed and controlled...

Страница 14: ...PT requirements of ANSI ASME B1 20 1 A minimum of 5 threads provided on each part MOUNTING RULE Thread cleaning with Loctite 7063 or equivalent product with similar efficiency Cemented with Loctite 27...

Страница 15: ...com Copyright 2021 Baker Hughes Company All rights reserved Baker Hughes provides this information on an as is basis for general information purposes Baker Hughes does not make any representation as t...

Отзывы: