background image

 

© 2021 Baker Hughes Company. All rights reserved. 

Masoneilan 7700E UA TR Instructions Manual | 11

 

 

10.  Maintenance 

 

 

Comply with current national and local regulations for electrical installation work. 

 

These operations must be done in conformance with national and local regulations 
applicable for explosive atmospheres 

 

Before carrying out any work on the device, power off the instrument or make sure that the local 
conditions in the potentially explosive atmosphere permit the safe opening of the cover. 

 

Before switching on or after doing any work on the device, always tighten the cover (C) with 
a seal (J) in good condition and put back the safety screw (V). 

 

 

Make sure that the components of the instrument are not damaged. In the event of damage replace the 

defective parts with genuine manufacturer's replacement parts. 

 

 

Pay particular attention to the following: 

o

 

General condition of the housing. 

o

 

Check the cable gland and the electrical connections. 

o

 

When replacing the  I/P  module, check the condition  of the three 'O' rings (K022, K023, K024) and 
replace them if necessary. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

The  user  shall  clean  the  equipment  regularly  to  avoid  dust  accumulating  on  the  walls,  for  instruments 

installed in Dust areas. See instruction 

§12.1  b & c 

for safe cleaning. 

 

Avoid contact of the apparatus with aggressive substances which could damage the metallic or plastic 

parts. 

 
 

11.  Conditions of Work 

A training session must be followed by person usually recognized to use apparatus in explosible 
atmospheres. 
This training session is not supported by Dresser Produits Industriels S.A.S.

 

 
 

pilotepilote

28

29

30

K023 

K022 

K024 

Содержание Masoneilan 7700E

Страница 1: ...Baker Hughes Data Classification Public Masoneilan Type 7700EElectro Pneumatic Positioner with I P 4000 Converter Ukrainian UA TR Instruction Manual Rev A...

Страница 2: ...REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN...

Страница 3: ...Assembly of a 7700E Positioner on a Valve 7 7 Pneumatic Connection of Positioner 7700E 7 8 Electrical Connection Installation and Start Up 7 8 1 Conduit entry in flameproof application 8 8 2 Electrica...

Страница 4: ...y qualified and competent professionals who have undergone suitable training for instrumentation used in areas with potentially explosive atmospheres Such trainings are not supported by Baker Hughes I...

Страница 5: ...pneumatic signal Model 7700E electro pneumatic positioner can be used only on Varipak valve 28000 2 Numbering System Unique positioner 7700 E with I P 4000 module Different versions Housing material...

Страница 6: ...Pi 0 33 W Li 0 Ci 0 IP66 Warning Potential electrostatic charging hazard See instructions for safe use 5 Flameproof Marking and Electrical Safety Parameters The marking on the serial plate stamped on...

Страница 7: ...Series instruction manual Ref 30857 for more details 7 Pneumatic Connection of Positioner 7700E Make sure that the air supply pressure is suitable for the installation and for the instrument When usin...

Страница 8: ...y on the single NPT ANSI ASME B1 20 1 housing conduit connection The cable entry has to be suitable to the equipment operating zone IP 6X for zones 20 21 and 22 If an adaptor or reducer is needed it m...

Страница 9: ...allation for explosible atmosphere with d protection mode Intrinsically safe installation for explosible atmosphere with ia protection mode Note It is under the user responsibility to check the instal...

Страница 10: ...ke sure that the local conditions in the potentially explosive atmosphere permit the safe opening of the cover Connect the wires to the instrument s terminals taking care of complying with polarities...

Страница 11: ...ment are not damaged In the event of damage replace the defective parts with genuine manufacturer s replacement parts Pay particular attention to the following o General condition of the housing o Che...

Страница 12: ...vertical position uppermost the required ingress protection against water is invalidated therefore it shall only be installed in this orientation if its location provides protection against falling wa...

Страница 13: ...ss 123112 Russia Moscow Presnenskaya embankment house 10 room III floor 3 room 22 Tel 7 495 739 68 11 MoscowHelpDesk bakerhughes com 14 Design and Manufactured by Products are designed and controlled...

Страница 14: ...PT requirements of ANSI ASME B1 20 1 A minimum of 5 threads provided on each part MOUNTING RULE Thread cleaning with Loctite 7063 or equivalent product with similar efficiency Cemented with Loctite 27...

Страница 15: ...com Copyright 2021 Baker Hughes Company All rights reserved Baker Hughes provides this information on an as is basis for general information purposes Baker Hughes does not make any representation as t...

Отзывы: