15
15
GETTING TO KNOW YOUR MACHINE
DUST-COLLECTING
This machine is equipped with a dust collection hood with one port. The dust collector is optional
and sold separately. Before the machine is used, make sure the dust collector work as
designed.
The minimum required air speed at the end of flexible tube is 20 m/sec. The minimum required
air volume of the machine is 750 m³/hr. (43,000~49,000 cu. ft./hr.). Use antistatic and electrically
conductive hoses only.
IMPORTANT:
Use care and planning when attaching and routing flexible hose for
dust collection. DO NOT create a trip hazard or an interference of the work station when routing
the hose(s).
The 4” (100mm) dust port is part of and on the end of the dust hood/guard.
When connecting the flexible hose, plan for:
•
The hose to travel with the hood when the machine
is converted between the jointing and planing
operations.
•
Positioning so as NOT to interfere with the operator
or the work piece.
•
Prevention of the hose from creating a trip or
entanglement hazard.
•
Having the hose secured to the port to prevent
accidental detachment during operation.