![Baileigh Industrial PT-105HD-W Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/baileigh-industrial/pt-105hd-w/pt-105hd-w_operators-manual_3454606042.webp)
39
39
Parameter Import
In the parameter configuration interface, press [F6] to
import the parameters. The parameters should satisfy
two conditions:
1. The parameters exported from the cutting machine
control system should satisfy the specified format.
The file format is F2300.DAT.
2. The file should be stored under the root folder of the
flash disk which is connected to the USB interface.
When the above condition is satisfied, press Enter to
confirm, and then you could import the backup parameters to the system.
Parameter Export
After the parameter configuration is over, press [F7] in the parameter configuration interface to
export the parameters, you should connect the flash disk to the USB interface before exporting.
The dialog box will display “Sure to export Parameter?”. If planning to export the parameters,
press ENTER, if not press ESC.
In the interface, after pressing Enter, the parameters will automatically be saved in the root folder
of the flash disk, the file name is F2300.DAT.
Save Parameters
After parameter modification, press [F8] to save the changes.
The dialog box will display “Parameter saved successfully” to indicate that the parameters have
been saved.
Note:
When any parameter has been modified, you must take preservation
operation to keep modification valid, or the system will take the original parameters.