Plasma Parameters
These are Plasma Parameters, which are related to the precision of the transmission shaft of the
machine.
Delay Before Arc
0.10 s
Pierce Time
0.19 s
Torch Up Time
0.26 s
Arcing Check Time
15.00 s
Position Check Time
10.00 s
Position Up Time
0.35 s
Speed to Lock THC
95.00 mmpm%
Distance to Lock THC
5.00 mm
Time of Disable THC After Piercing
0.00 s
Lose Arc Delay
0.00 s
Time to Lock THC before M08
0.00 s
Watch Arc Enable
⃣√
Use Cylinder THC
⃣
Set Arc Voltage
130.00
V
Arc Protection Value
30.00
V
THC Sensitivity
40.00
%
Arc Set Step Value
1.00
V
Fast IHS Time
6.00
s
Flame Updown Speed
100.00
%
Plasma Updown Speed
100.00
%
Pierce Count
000
Clear
Workpiece Count 000
Clear
Cut Length (m)
0.00 Clear
Cut Time
00:00:00
clear
Run Time
00:00:00
clear
F1
Common
F2
Flame
F3
Plasma
F5
System
F6
Import
F7
Export
F8 Save
•
Delay Before Arc: Before the arc starts, the system time to wait. At this point, all output I/O are
turned off. Enter any positive number, unit is s.
•
Pierce time: Perforation time. Enter any positive number, unit is s.
•
Torch Up Time: When arc press is turned off, the time for the torch to lift up. Enter any positive
number, unit is s.
•
Arcing Check Time: If not detected any feedback signal of success arc starting within the
detection time, the system prompts an error message and terminates the current work of
cutting, according memory breakpoints to withdraw from the program. Enter any positive
number, unit is s.