24V motor control device for flush box mounting - Version 1.1
Instruction manual
15/22
6
Initial operation
w w w .b ai e r- g mb h .d e
6.2
Steps during initial operation
W A R N I N G
Moving wing
Danger of injury by squashing, shearing or collision, caused
by moving wing.
Wing moves independently during initial operation.
Keep danger area clear during initial operation.
Prepare eletrical connections
Refer to chapter 5.4
Set configuration
Refer to chapter 6.1
Switch power supply on
Control device in delivery status or after power cut:
Red LED blinks continuously twice with a short break of 1.5 sec
Press RESET for 2 seconds
Red LED blinks continuosly
Check driving direction of motor
When pressing OPEN, wing has to open and when pressing CLOSE, wing has
to close
When driving direction is wrong:
Swap motor cables (clamp 4 and 5), check driving direction again
Press RESET again for 2 seconds
Red LED lights up permanently,
Green LED lights up, when motor is active
Drive performs a few runs.
LEDs go out
Red LED starts blinking continuosly
In this state (about 30 seconds) additional complete cycles may be performed.
These cycles have to be triggered by user and are optional.
After 30 seconds without any function, the LED goes out
Check desired function
In case of malfunction, check electrical connections and configuration
Electrical connection, refer to chapter 5.4
Configuration, refer to chapter 6.1
Repeat initial operation, if necessary
Initial operation is completed, when function is correct
Prepare control device
Reset control device
Check function
…
…
…
…
Содержание PROMETHEUS Series