| 19 |
c) Disconnect the plug of the drill or drive unit
from the socket before mounting the drill or
drive unit on the drill stand, make any unit
settings or change accessory parts.
Unintentional starting of drills or drive units
causes accidents.
d) Fix the drill or drive unit securely onto the
drill stand as specified before starting work.
Slipping of the drill or drive unit on the drill stand
can cause loss of control and injuries.
e) Remove all setting tools, spanners and
installation materials not required before
switching on the drill or drive unit.
Setting tools, spanners and installation materials
located in/on a rotating part of the tool can result
in injuries.
f) Do not overload the drill stand and do not
use it as a ladder or scaffolding.
Overloading or standing on the drill stand can
cause the centre of gravity of the drill stand to
move upwards and the drill stand overturns.
g) Keep the handles and gripping surfaces dry,
clean and free from oil and grease.
Slippery handles and gripping surfaces prevent
safe operation and control of the drill stand in
unforeseen situations.
h) When fixing the drill stand on the workpiece
using anchors and screws, ensure that the
anchoring used is able to hold the machine
safely during use.
If the workpiece is not resistant or is porous, the
anchor can be pulled out, which causes the drill
stand to detach from the workpiece.
i) If fixing the drill stand on the workpiece by
means of a vacuum plate, ensure that the
surface is smooth, clean and not porous. Do
not fix the drill stand onto laminated surfac
es, such as tiles and facings of composite
materials.
If the surface of the workpiece is not smooth,
flat or adequately fixed, the vacuum plate can
detach from the workpiece.
NOTE
The above safety instruction only applies if it is
planned to use the tool with a vacuum plate.
j) Before and while drilling, ensure that the
vacuum is sufficient.
If the vacuum is insufficient, the vacuum plate
can detach from the workpiece.
NOTE
The above safety instruction only applies if it is
planned to use the tool with a vacuum plate.
k) Never carry out overhead drilling and drill
ing, if the drill stand is fixed on the machine
by means of a vacuum plate only.
In the event of loss of vacuum, the vacuum plate
detaches from the workpiece.
NOTE
The above safety instruction only applies if it is
planned to use the tool with a vacuum plate.
Use RAWL anchors with diameter 20 mm / M12
for fixing onto walls.
l) Do not use any accessories that have not
been especially provided and recommended
for this drill stand by the manufacturer.
Just because you can attach accessories to your
drill stand is not a guarantee of safe use.
m) Additional signs or other, nonBAIERspecif
ic parts must not be screwed or riveted onto
the drill stand.
This could damage the drill stand and cause
malfunctions to occur.
n) Note and follow all safety and work instruc
tions for the accessories used.