45
5.4
Terminals
5.4.1
Location of the terminals
Figure 16, Location of the terminals (Housing for panel mounting)
Figure 17, Location of the terminals (19”-rack)
5.4.2
Connector X1 (Supply voltage)
Type of connector:
Combicon MSTB2,5/3-ST-5,08 (Phoenix)
Function:
DLX mains power supply connector
Supply voltage:
60VDC – 270VDC and
85VAC – 265VAC
Fuse:
T 2A 250V
Power consumption
max. 20VA
Terminal Description
AC
DC
1
Line
L1
60-270VDC
2
Neutral
N
0VDC
3
Protective
Earth
PE
PE
Figure 18, Connector X1 (Supply voltage)