Installing the Encoder
INSTALLING THE ENCODER
Bayonet Mount
The fully potted assembly has a bayonet mount compatible with all Recordall Disc, Turbo Series, Compound Series, Combo
Series and Fire Series meters and assemblies .
The bayonet mount positions the encoder in any of four orientations for visual reading convenience . The device can be
removed from the meter without disrupting water service .
The device is permanently sealed to eliminate the intrusion of moisture, dirt or other contaminants, and is suitable for
installation in all environments, including meter pits subject to continuous submergence .
Install the device on the water meter and secure it using the tamper-proof screw provided .
Wire Connections
The following connection options are available . For more information on in-line connectors, refer to the document,
ORION
Water Endpoints Installation Manual
, available at
HR-E LCD
The HR-E LCD encoder has a single cable, available with three different wiring options . Refer to
•
In-line connector
•
Flying lead for field splice connection
•
Prewired to an AMR/AMI endpoint
Encoder Cable with In-line Connector
Flying Lead
RED - Power
GREEN - Data
BLACK - Ground
Prewired to AMR/AMI Endpoint
Figure 2: HR-E LCD wiring options
HR-E LCD 4-20
The HR-E LCD 4-20 encoder is available with dual output wire connections . Refer to
.
Encoder side cable
•
In-line connector
•
Flying lead for field splice connection
4-20 side cable
•
Flying lead for field splice connection
4-20 mA Cable
RED - Loop/External Power +
BLACK - Loop Return/External Power
–
Encoder Cable with In-line Connector
4-20 mA Cable
RED - Power
GREEN - Data
BLACK - Ground
Encoder Cable with Flying Lead
RED - Loop/External Power +
BLACK - Loop Return/External Power
–
Figure 3: HR-E LCD 4-20 wiring options